. 2018 May 15;14(5):841-848.
doi: 10.5664/jcsm.7120.

Ability of the Multisensory Jawbone UP3 to Quantify and Classify Sleep in Patients With Suspected Central Disorders of Hypersomnolence: A Comparison Against Polysomnography and Actigraphy

Affiliations
Comparative Study

Ability of the Multisensory Jawbone UP3 to Quantify and Classify Sleep in Patients With Suspected Central Disorders of Hypersomnolence: A Comparison Against Polysomnography and Actigraphy

Jesse D Cook et al. J Clin Sleep Med. .

Abstract

Study objectives: To evaluate the ability of a multisensory fitness tracker, the Jawbone UP3 (JB3), to quantify and classify sleep in patients with suspected central disorders of hypersomnolence.

Methods: This study included 43 patients who completed polysomnography (PSG) and a Multiple Sleep Latency Test (MSLT) with concurrent wrist-worn JB3 and Actiwatch 2 (AW2) recordings for comparison. Mean differences in nocturnal sleep architecture variables were compared using Bland-Altman analysis. Sensitivity, specificity, and accuracy were derived for both devices relative to PSG. Ability of the JB3 to detect sleep onset rapid eye movement periods (SOREMPs) during MSLT naps was also quantified.

Results: JB3 demonstrated a significant overestimation of total sleep time (39.6 min, P < .0001) relative to PSG, but performed comparably to AW2. Although the ability of the JB3 to detect epochs of sleep was relatively good (sensitivity = 0.97), its ability to distinguish light, deep, and REM sleep was poor. Similarly, the JB3 did not correctly identify a single SOREMP during any MSLT nap opportunity.

Conclusions: The JB3 did not accurately quantify or classify sleep in patients with suspected central disorders of hypersomnolence, and was particularly poor at identifying REM sleep. Thus, this device cannot be used as a surrogate for PSG or MSLT in the assessment of patients with suspected central disorders of hypersomnolence.

Keywords: Jawbone; actigraphy; fitness tracker; hypersomnolence; sleep; sleepiness.

PubMed Disclaimer

Figures

Figure 1
Figure 1. Bland-Altman comparison of JB3 and PSG.
Bland-Altman plots presenting the mean difference values of the JB3 and PSG on the y-axis against PSG values on the x-axis. Horizontal, solid red line denotes the average mean difference with dotted lines representing 95% confidence interval. DS = deep sleep, JB3 = Jawbone UP3, LS = light sleep, PSG = polysomnography, REML = rapid eye movement sleep latency, SE = sleep efficiency, SOL = sleep onset latency, TRT = total rapid eye movement sleep time, TST = total sleep time, WASO = wake after sleep onset.
Figure 2
Figure 2. Bland-Altman comparison of JB3 and AW2.
Bland-Altman plots presenting the mean difference values of the JB3 and AW2 on the y-axis against the mean average values of the JB3 and AW2 on the x-axis. Horizontal, solid red line denotes the average mean difference with dotted lines representing 95% confidence interval. AW2 = Actiwatch 2, JB3 = Jawbone UP3, SE = sleep efficiency, SOL = sleep onset latency, TST = total sleep time, WASO = wake after sleep onset.
Figure 3
Figure 3. Bland-Altman comparison of AW2 and PSG.
Bland-Altman plots presenting the mean difference values of the AW2 and PSG on the y-axis against PSG values on the x-axis. Horizontal, solid red line denotes the average mean difference with dotted lines representing 95% confidence interval. AW2 = Actiwatch 2, PSG = polysomnography, SE = sleep efficiency, SOL = sleep onset latency, TST = total sleep time, WASO = wake after sleep onset.

References

    1. American Academy of Sleep Medicine. International Classification of Sleep Disorders. 3rd ed. Darien, IL: American Academy of Sleep Medicine; 2014.
    1. Khan Z, Trotti LM. Central disorders of hypersomnolence: focus on the narcolepsies and idiopathic hypersomnia. Chest. 2015;148(1):262–273. - PMC - PubMed
    1. Boon P, Pevernagie D, Schrans D. Hypersomnolence and narcolepsy; a pragmatic diagnostic neurophysiological approach. Acta Neurol Belg. 2002;102(1):11–18. - PubMed
    1. Bozluolcay M, Nalbantoglu M, Benbir Senel G, Karadeniz D. What does one sleep-onset rem period—during either nocturnal polysomnography or multiple sleep latency test—mean in differential diagnosis of central hypersomnias? J Clin Neurophysiol. 2015;32(4):364–368. - PubMed
    1. Littner MR, Kushida C, Wise M, et al. Practice parameters for clinical use of the Multiple Sleep Latency Test and the Maintenance of Wakefulness Test. Sleep. 2005;28(1):113–121. - PubMed