Quadripolar Leads in Cardiac Resynchronization Therapy
Abstract
Despite the benefit of cardiac resynchronization therapy (CRT) in patients with heart failure and conduction delay, a considerable number of patients do not respond substantially. Left ventricular lead position is an important factor in response, restricted by the patient's specific anatomy and local pathophysiology. Quadripolar leads could enhance response to CRT, offering 4 pacing locations along the distal end of the lead. Several quadripolar leads are available, all with different shapes and electrode spacing. Electrodes can be positioned in an ideal pacing location, determined by delayed mechanical or electrical activation, and away from phrenic nerve stimulation, high pacing thresholds, and fibrosis. Implantation is safe, with comparable or even lower complication rates compared with standard bipolar leads. Studies on biventricular pacing with quadripolar leads show apparent variations in acute hemodynamic response between pacing configurations, implying a patient-specific response. Pacing with an optimal pacing vector of a quadripolar lead benefits acute hemodynamic response. Multipoint pacing, pacing the left ventricle with 2 of 4 electrodes, could further enhance response. However, larger trials are needed to confirm these results, and results on long-term outcome of CRT with quadripolar leads and the benefit of multipoint pacing are warranted. We conclude that quadripolar leads are an important improvement in the treatment of heart failure patients with CRT.
Keywords: cardiac resynchronization therapy; lead; multipoint pacing; phrenic nerve stimulation; quadripolar.
Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Similar articles
-
The use of quadripolar left ventricular leads improves the hemodynamic response to cardiac resynchronization therapy.Pacing Clin Electrophysiol. 2015 Mar;38(3):326-33. doi: 10.1111/pace.12545. Epub 2014 Dec 9. Pacing Clin Electrophysiol. 2015. PMID: 25492127
-
Effectiveness and Reliability of Selected Site Pacing for Avoidance of Phrenic Nerve Stimulation in CRT Patients with Quadripolar LV Leads: The EffaceQ Study.Pacing Clin Electrophysiol. 2015 Aug;38(8):942-50. doi: 10.1111/pace.12664. Epub 2015 Jun 12. Pacing Clin Electrophysiol. 2015. PMID: 25974406
-
Improvement in hemodynamic response using a quadripolar LV lead.Pacing Clin Electrophysiol. 2013 Aug;36(8):963-9. doi: 10.1111/pace.12172. Epub 2013 May 21. Pacing Clin Electrophysiol. 2013. PMID: 23692289
-
Profile of St. Jude Medical's Allure Quadra quadripolar pacemaker system for cardiac resynchronization therapy.Expert Rev Med Devices. 2015 Jan;12(1):41-8. doi: 10.1586/17434440.2015.984686. Epub 2014 Nov 22. Expert Rev Med Devices. 2015. PMID: 25418543 Review.
-
A comparison of the different features of quadripolar left ventricular pacing leads to deliver cardiac resynchronization therapy.Expert Rev Med Devices. 2017 Sep;14(9):697-706. doi: 10.1080/17434440.2017.1369404. Epub 2017 Aug 23. Expert Rev Med Devices. 2017. PMID: 28835138 Review.
Cited by
-
Six months clinical outcome comparison between quadripolar and bipolar left ventricular leads in cardiac resynchronization therapy: A prospective, non-randomized, single-centre observational study.Indian Pacing Electrophysiol J. 2021 May-Jun;21(3):162-168. doi: 10.1016/j.ipej.2021.02.009. Epub 2021 Feb 23. Indian Pacing Electrophysiol J. 2021. PMID: 33636279 Free PMC article.
-
Quadripolar left ventricle only single lead pacing in a patient with a tricuspid mechanical valve: A less invasive approach.J Cardiol Cases. 2022 Dec 1;27(3):105-107. doi: 10.1016/j.jccase.2022.11.004. eCollection 2023 Mar. J Cardiol Cases. 2022. PMID: 36910037 Free PMC article.
-
Contrast-induced nephropathy after cardiac resynchronization therapy implant impairs the recovery of ejection fraction in responders.ESC Heart Fail. 2019 Dec;6(6):1266-1273. doi: 10.1002/ehf2.12523. Epub 2019 Dec 12. ESC Heart Fail. 2019. PMID: 31833232 Free PMC article.
-
Efficacy, Safety, and Performance of Isolated Left vs. Right Ventricular Pacing in Patients with Bradyarrhythmias: A Randomized Controlled Trial.Arq Bras Cardiol. 2019 Apr;112(4):410-421. doi: 10.5935/abc.20180275. Epub 2019 Apr 15. Arq Bras Cardiol. 2019. PMID: 30994720 Free PMC article. Clinical Trial.
-
Long-Term Performance Comparison of Bipolar Active vs. Quadripolar Passive Fixation Leads in Cardiac Resynchronisation Therapy.Front Cardiovasc Med. 2021 Nov 22;8:734666. doi: 10.3389/fcvm.2021.734666. eCollection 2021. Front Cardiovasc Med. 2021. PMID: 34881300 Free PMC article.
Publication types
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials