Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1988;60(2):131-7.
doi: 10.1007/BF00202900.

Superimposing noise linearizes the responses of primary muscle spindle afferents to sinusoidal muscle stretch

Affiliations

Superimposing noise linearizes the responses of primary muscle spindle afferents to sinusoidal muscle stretch

J Kröller et al. Biol Cybern. 1988.

Abstract

Experiments were conducted in anaesthetized and spinalized cats to measure the extent to which the non-linear response of Ia afferent fibers to sinusoidal muscle stretch as expressed by the peristimulus-time-histograms, PSTHs, can be transformed into a linear one by means of the superposition of random stretch ("mechanical noise"). The gastrocnemius muscles of one hind leg were stretched and the response to sinewave muscle stretch (amplitudes between 0.01 and 4.0 mm, frequencies between 0.1 and 20 Hz) were investigated while band-limited mechanical noise was superimposed on the sinewave stretch. The random stretch upper cut-off frequency was varied between 60 and 300 Hz; the displacements were normally distributed. The noise amplitude sigma, i.e. the standard deviation of the displacement distributions, was varied systematically between 0.002 and 0.4 mm. Mechanical noise was very effective in raising the mean discharge rate. Added to the sinusoidal stretch it prevented the cessation of firing during the release phase of the stretch cycle, or at least reduced the duration of discharge pauses, i.e., a linearization occurred. In general, the larger the noise amplitude, the more the amplitude of the fundamental harmonic component was attenuated and the phase lead reduced. Apart from this rule the particular combination of superimposing small noise (sigma less than 0.02 mm) on small sinewave stretch (A less than 0.02 mm) could enhance the depth of sinusoidal modulation of cycle histograms (compared with responses to pure sinusoids). Linearizing the sinewave response by additional noise allowed the estimation of frequency response characteristics in the otherwise non-linear range of amplitudes (sinewave amplitude 0.5-1.0 mm).(ABSTRACT TRUNCATED AT 250 WORDS)

PubMed Disclaimer

References

    1. Prog Brain Res. 1976;44:89-98 - PubMed
    1. J Physiol. 1981 Aug;317:365-81 - PubMed
    1. Pflugers Arch Gesamte Physiol Menschen Tiere. 1968 Apr 23;300(3):161-84 - PubMed
    1. Exp Brain Res. 1977 Sep 28;29(3-4):367-85 - PubMed
    1. Pflugers Arch. 1970;315(1):1-26 - PubMed

Publication types

LinkOut - more resources