Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Case Reports
. 2017 Dec 1;5(6):181-183.
doi: 10.12945/j.aorta.2017.17.056. eCollection 2017 Dec.

Use of Iliac Branch Device for Endovascular Treatment for Abdominal Aorta Aneurysm with Small Diameter Neck

Affiliations
Case Reports

Use of Iliac Branch Device for Endovascular Treatment for Abdominal Aorta Aneurysm with Small Diameter Neck

Umberto G Rossi et al. Aorta (Stamford). .

Abstract

We present the case of a 78-year-old woman with a 4.5-cm symptomatic abdominal aortic aneurysm with a small diameter (13-mm diameter) infrarenal aortic neck who underwent endovascular treatment using an iliac branch device as a bifurcated aortic stent-graft.

Keywords: Abdominal aorta aneurysm; Elderly patients; Endovascular treatment; Iliac branch device.

PubMed Disclaimer

Figures

Figure 1.
Figure 1.
Panel A. Multidetector computed tomography coronal volume rendering technique demonstrating the abdominal aorta aneurysm lumen. Panel B. Infrarenal aortic neck 13 mm in diameter. Panel C. Length from renal arteries to iliac bifurcation of 65.1 mm.
Figure 2.
Figure 2.
Panel A. Digital subtraction angiography of abdominal aorta with the iliac branch device with its proximal stent below the left renal artery. Panel B. Final digital subtraction angiography of the abdominal aorta confirming correct positioning of the devices.
Figure 3.
Figure 3.
Multidetector computed tomography coronal volume rendering technique at 1 year demonstrating abdominal aorta aneurysm exclusion with patency of the endograft.

References

    1. Jackson BM, Carpenter JP. Devices used for endovascular aneurysm repair: past, present, and future. Semin Intervent Radiol.2009;26:39-43. DOI: 10.1055/s-0029-1208382 - DOI - PMC - PubMed
    1. Shiraev TP, Dubenec S. Novel use of an iliac branch device in the treatment of an abdominal aortic aneurysm. Ann Vasc Surg.2016;34:272.e1-e4. DOI: 10.1016/j.avsg.2016.01.014 - DOI - PubMed
    1. Cariati M, Mingazzini P, Dallatana R, Rossi UG, Settembrini A, Santuari D. Endovascular treatment of a symptomatic thoracoabdominal aortic aneurysm by chimney and periscope techniques for total visceral and renal arteries revascularization. Cardiovas Intervent Radiol.2014;37:251-256. DOI: 10.1007/s00270-013-0622-2 - DOI - PubMed

Publication types