Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Feb;21(2):173-177.
doi: 10.1177/1098612X18767570. Epub 2018 May 18.

Incidence of arterial catheter complications: a retrospective study of 35 cats (2010-2014)

Affiliations

Incidence of arterial catheter complications: a retrospective study of 35 cats (2010-2014)

Shaina Mooshian et al. J Feline Med Surg. 2019 Feb.

Abstract

Objectives: The aim of this study was to investigate the incidence of complications associated with arterial catheterization in cats in a veterinary hospital, and to document which factors may increase the incidence of complications.

Methods: Medical records at a referral veterinary hospital were retrospectively reviewed to identify cats that had an arterial catheter placed between January 2010 and October 2014.

Results: Thirty-five cats having 38 arterial catheters were included in the study. There was a relatively high incidence of minor complications (23.7%), with the most common being catheter occlusion. The incidence of major arterial catheter complications was low (2.63%). Duration of catheter use was positively correlated to the incidence of complications. There was also a significant correlation between catheters used for intensive care unit monitoring and incidence of complications. All cats with catheter complications survived to discharge.

Conclusions and relevance: The low incidence of major arterial catheter complications in this population of cats illustrates that arterial catheterization is a safe monitoring and diagnostic tool. The duration of catheter placement is significantly associated with the incidence of catheter complications.

PubMed Disclaimer

Conflict of interest statement

The authors declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article.

References

    1. Parasuraman A, Raveendran R. Measurement of invasive blood pressure in rats. J Pharmacol Pharmacother 2012; 3: 172–177. - PMC - PubMed
    1. Zwijnenberg RJ, del Rio CL, Cobb RM, et al. . Evaluation of oscillometric and vascular access port arterial blood pressure measurement techniques versus implanted telemetry in anesthetized cats. Am J Vet Res 2011; 72: 1015–1021. - PubMed
    1. Beal MW, Hughes D. Vascular access: theory and techniques in the small animal emergency patient. Clin Tech Small Anim Pract 2000; 15: 101–109. - PubMed
    1. Scheer BV, Perel A, Pfeiffer UJ. Clinical review: complication and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine. Crit Care 2002; 6: 199–204. - PMC - PubMed
    1. Koh DB, Gowardman JR, Rickard CM, et al. . Prospective study of peripheral arterial catheter infection and comparison with concurrently sited central venous catheters. Crit Care Med 2008; 36: 397–402. - PubMed

MeSH terms

LinkOut - more resources