Case Reports
. 2018 Jun;66(6):861-862.
doi: 10.4103/ijo.IJO_987_17.

A microinvasive technique for management of corneal edema secondary to glaucoma drainage device tube-corneal touch

Affiliations
Case Reports

A microinvasive technique for management of corneal edema secondary to glaucoma drainage device tube-corneal touch

Harsh Kumar et al. Indian J Ophthalmol. 2018 Jun.

Abstract

We present a case of tube endothelial touch where a suture technique for repositioning of the Ahmed glaucoma valve was performed. Advantage of this technique is that it is minimally invasive and anterior chamber stability is maintained during the procedure.

Keywords: Ahmed glaucoma valve; glaucoma drainage device; tube-corneal touch.

PubMed Disclaimer

Conflict of interest statement

There are no conflicts of interest

Figures

Figure 1
Figure 1
Tube-corneal touch. Localized central corneal edema is shown by the black arrow
Figure 2
Figure 2
After tube repositioning using 9–0 Prolene suture

Similar articles

References

    1. Hong CH, Arosemena A, Zurakowski D, Ayyala RS. Glaucoma drainage devices: A systematic literature review and current controversies. Surv Ophthalmol. 2005;50:48–60. - PubMed
    1. Weiner A, Cohn AD, Balasubramaniam M, Weiner AJ. Glaucoma tube shunt implantation through the ciliary sulcus in pseudophakic eyes with high risk of corneal decompensation. J Glaucoma. 2010;19:405–11. - PubMed
    1. Sarkisian SR., Jr Tube shunt complications and their prevention. Curr Opin Ophthalmol. 2009;20:126–30. - PubMed
    1. Law SK, Coleman AL, Caprioli J. Dynamic tube movement of Ahmed glaucoma valve. J Glaucoma. 2009;18:628–31. - PubMed
    1. McDermott ML, Swendris RP, Shin DH, Juzych MS, Cowden JW. Corneal endothelial cell counts after Molteno implantation. Am J Ophthalmol. 1993;115:93–6. - PubMed

Publication types