Adenovirus pseudo-outbreak in a large UK neonatal intensive care unit
- PMID: 29799422
- DOI: 10.1016/j.ajic.2018.04.220
Adenovirus pseudo-outbreak in a large UK neonatal intensive care unit
Abstract
An unusually high number of positive adenovirus stool antigen tests were observed in neonatal samples from a large tertiary referral unit over a 10-week period, prompting the declaration of an outbreak and escalation of infection control precautions. Subsequent testing of original samples by alternative methods revealed a series of false-positive results. This is the first adenovirus pseudo-outbreak to be reported in the United Kingdom and the first to involve the Proflow Rotavirus-Adenovirus Combi test.
Keywords: Adenovirus; NICU; Neonatal; Pseudo-outbreak; Rotavirus-adenovirus combi test; Stool antigen test.
Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.