Validation of the ipsilateral nipple as the needle directional guide during right internal jugular vein catheterization: A prospective observational study
- PMID: 29804710
- DOI: 10.1016/j.asjsur.2018.04.003
Validation of the ipsilateral nipple as the needle directional guide during right internal jugular vein catheterization: A prospective observational study
Abstract
Background: The ipsilateral nipple has been used as a directional guide for needle advance during internal jugular vein (IJV) catheterization. We attempted to validate the utility of the ipsilateral nipple during IJV catheterization.
Methods: One hundred and two patients scheduled for elective surgery were enrolled. In the 15° Trendelenberg position with 30° head rotation, the apex of the triangle formed by the sternocleidomastoid muscle and the clavicle was identified. The angle formed by the line connecting the apex and the ipsilateral nipple and the actual course of the IJV was measured. The distance between the apex of the anatomical triangle and the IJV center identified were measured via ultrasound.
Results: The angle formed by the line connecting the apex and the ipsilateral nipple and the IJV was 16 ± 7.6° and was greater in females than males (14.8 ± 1.1 vs 17.4 ± 1.0°, P = 0.043). Regression analysis showed that height, weight, gender, and age did not affect the angle as an independent factor. The apex of the anatomical triangle was 0.5 cm medial to the IJV center and was shorter in females compared to males (0.33 ± 0.12 vs 0.6 ± 0.09 cm, P = 0.039).
Conclusion: Our study shows that when the needle is inserted at the apex of the anatomical triangle directed towards the ipsilateral nipple, it crosses the IJV at 16°. Since the common carotid artery is usually medial to the IJV, directing the needle towards the ipsilateral nipple seems to be a safe way to avoid the common carotid artery and successfully puncture the IJV.
Keywords: Common carotid artery; Internal jugular vein catheterization; Ipsilateral nipple.
Copyright © 2018. Published by Elsevier Taiwan LLC.
Similar articles
-
Ultrasound evaluation of the anatomical characteristics of the internal jugular vein and carotid artery--facilitation of internal jugular vein cannulation.Middle East J Anaesthesiol. 2008 Oct;19(6):1305-20. Middle East J Anaesthesiol. 2008. PMID: 18942245 Clinical Trial.
-
A randomized study of a new landmark-guided vs traditional para-carotid approach in internal jugular venous cannulation in infants.Paediatr Anaesth. 2009 May;19(5):481-6. doi: 10.1111/j.1460-9592.2009.02989.x. Paediatr Anaesth. 2009. PMID: 19453580 Clinical Trial.
-
Head rotation during internal jugular vein cannulation and the risk of carotid artery puncture.Anesth Analg. 1996 Jan;82(1):125-8. doi: 10.1097/00000539-199601000-00022. Anesth Analg. 1996. PMID: 8712386
-
Horner Syndrome Caused by Internal Jugular Vein Catheterization.J Cardiothorac Vasc Anesth. 2020 Jun;34(6):1636-1640. doi: 10.1053/j.jvca.2019.06.031. Epub 2019 Jun 28. J Cardiothorac Vasc Anesth. 2020. PMID: 31350153 Review.
-
The "medial-oblique" approach to ultrasound-guided central venous cannulation--maximize the view, minimize the risk.J Cardiothorac Vasc Anesth. 2012 Dec;26(6):982-4. doi: 10.1053/j.jvca.2012.04.013. Epub 2012 Jun 9. J Cardiothorac Vasc Anesth. 2012. PMID: 22683157 Review.