Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2018 Oct;33(10):1479-1483.
doi: 10.1007/s00384-018-3093-8. Epub 2018 May 28.

A comparison of surgical devices for grade II and III hemorrhoidal disease. Results from the LigaLongo Trial comparing transanal Doppler-guided hemorrhoidal artery ligation with mucopexy and circular stapled hemorrhoidopexy

Affiliations
Free article
Randomized Controlled Trial

A comparison of surgical devices for grade II and III hemorrhoidal disease. Results from the LigaLongo Trial comparing transanal Doppler-guided hemorrhoidal artery ligation with mucopexy and circular stapled hemorrhoidopexy

Aurelien Venara et al. Int J Colorectal Dis. 2018 Oct.
Free article

Abstract

Purpose: Little is presently known on the impact of device type for Doppler-guided hemorrhoidal artery ligation/mucopexy (DGHAL) or circular stapled hemorrhoidopexy (CSH) when a surgical treatment is considered for hemorrhoidal disease (HD). In this study, we aimed to compare the outcome in terms of adverse events and recurrence rate, of patients included in the multicenter LigaLongo RCT ( ClinicalTrials.gov NCT01240772) according to the type of devices used.

Methods: In the DGHAL arm (N = 193), the procedure was done with transanal hemorrhoidal dearterialization (THD)™ (THD, Correggio, Italy) (104 patients) and with HAL-RAR™ (Agency for Medical Innovations (AMI) GmbH, Feldkirch, Austria) (89 patients). In the CSH arm (N = 184), procedure for prolapse and hemorrhoids (PPH)-03™ (Ethicon Endo-Surgery, Cincinnati OH) and hemorrhoidopexy and prolapse (HEM)™ (Covidien, Inc.) staplers were used in respectively 106 and 78 cases. Surgery-related morbidity at 90 postoperative days (POD) based on the Clavien-Dindo procedure-related complication score and clinical outcome in terms of recurrence and reoperation rate at 12 postoperative months (POM) was collected.

Results: Three hundred and seventy-seven patients were randomized according to HD grade. In the DGHAL arm, the number of ligations and mucopexies was higher in the AMI group (p < 0.0001); at 90 POD, the overall morbidity was similar between the two groups. In the CSH arm, donut sizes were similar; at 90 POD, the PPH group had a higher risk of postoperative grade 1 morbidity (anal urgency or incontinence) compared to the HEM group (p = 0.003). At 12 POM, no statistical difference was found between the two groups of each arm in terms of grade III recurrence or reoperation.

Conclusion: Postoperative morbidity and outcome at 1 year were similar regardless of the type of devices used. These findings suggest that device type has little impact on HD treatment results.

Trial registration: clinicaltrials.gov -Identifier NCT01240772.

Keywords: Circular staplers; Comparative outcome; Doppler-guided artery ligation devices; Hemorrhoidal disease; Multicenter randomized trial.

PubMed Disclaimer

References

    1. Int J Colorectal Dis. 2006 Jan;21(1):38-43 - PubMed
    1. Int J Surg. 2016 Apr;28:39-44 - PubMed
    1. Colorectal Dis. 2008 Sep;10(7):694-700 - PubMed
    1. Ann Surg. 2016 Nov;264(5):710-716 - PubMed
    1. Health Technol Assess. 2016 Nov;20(88):1-150 - PubMed

Publication types

Associated data

LinkOut - more resources