Low-dose anticoagulation after isolated mechanical aortic valve replacement with Liva Nova Bicarbon prosthesis: A post hoc analysis of LOWERING-IT Trial
- PMID: 29849105
- PMCID: PMC5976641
- DOI: 10.1038/s41598-018-26528-9
Low-dose anticoagulation after isolated mechanical aortic valve replacement with Liva Nova Bicarbon prosthesis: A post hoc analysis of LOWERING-IT Trial
Abstract
Thromboembolic complications after cardiac valve replacement are due to a complex interplay between patients' characteristics, device features and anticoagulation intensity. Subtle design and material differences in available prostheses may thrombosis. We conducted a post-hoc sub-analysis of the LOWERING-IT database to test the safety and feasibility of a low-level oral anticoagulant regime in low-risk patients with aortic LivaNova prosthetic valve replacement. The study population included 148 patients randomized to a low INR target (1.5-2.5; LOW-INR group), and 144 patients to the standard INR (2.0-3.0; CONVENTIONAL-INR group). The non-inferiority of thromboembolic events between LOW-INR and CONVENTIONAL-INR groups was tested. Cumulative follow-up reached 1,545 patient/years. The mean INR was 1.91 ± 0.23 in the LOW-INR group, and 2.59 ± 0.26 in the CONVENTIONAL-INR group (P < 0.001). There were 3 thromboembolic events, all in the CONVENTIONAL-INR group. Comparison of thromboembolic events was not significant. The 1-sided 97.5% exact CI for the difference in primary event proportion was 0.54%, satisfying criteria non-inferiority. Bleeding events were significantly different: 6.61 per 1,000 patient-year in LOW-INR group vs 18.65 per 1,000 patient-year in CONVENTIONAL-INR group (p < 0.045, RR 0.37). In conclusions these data suggest that low-dose anticoagulation is safe in selected patients after aortic LivaNova Bicarbon prosthesis implantation.
Conflict of interest statement
The authors declare no competing interests.
Figures
Similar articles
-
LOWERing the INtensity of oral anticoaGulant Therapy in patients with bileaflet mechanical aortic valve replacement: results from the "LOWERING-IT" Trial.Am Heart J. 2010 Jul;160(1):171-8. doi: 10.1016/j.ahj.2010.05.005. Am Heart J. 2010. PMID: 20598989 Clinical Trial.
-
Reduced anticoagulation after mechanical aortic valve replacement: interim results from the prospective randomized on-X valve anticoagulation clinical trial randomized Food and Drug Administration investigational device exemption trial.J Thorac Cardiovasc Surg. 2014 Apr;147(4):1202-1210; discussion 1210-1. doi: 10.1016/j.jtcvs.2014.01.004. Epub 2014 Jan 12. J Thorac Cardiovasc Surg. 2014. PMID: 24512654 Clinical Trial.
-
Low target-INR anticoagulation is safe in selected aortic valve patients with the Medtronic Open Pivot mechanical prosthesis: long-term results of a propensity-matched comparison with standard anticoagulation.Interact Cardiovasc Thorac Surg. 2017 Jun 1;24(6):862-868. doi: 10.1093/icvts/ivx028. Interact Cardiovasc Thorac Surg. 2017. PMID: 28329135
-
Improvement of oral anticoagulation therapy by INR self-management.J Heart Valve Dis. 2004 May;13(3):335-8. J Heart Valve Dis. 2004. PMID: 15222277 Review.
-
Optimal Intensity of Warfarin Therapy in Patients With Mechanical Aortic Valves.J Pharm Pract. 2019 Feb;32(1):93-98. doi: 10.1177/0897190017734765. Epub 2017 Oct 5. J Pharm Pract. 2019. PMID: 28982306 Review.
Cited by
-
Thirty-year outcomes of low-intensity anticoagulation for mechanical aortic valve.Heart Vessels. 2024 Jun;39(6):549-555. doi: 10.1007/s00380-024-02365-x. Epub 2024 Feb 23. Heart Vessels. 2024. PMID: 38393378
-
Anticoagulation after mechanical aortic valve implantation: is it time to act after PROACT?Ann Transl Med. 2018 Nov;6(Suppl 1):S16. doi: 10.21037/atm.2018.09.08. Ann Transl Med. 2018. PMID: 30613591 Free PMC article. No abstract available.
-
Apixaban in a porcine model of mechanical valve thrombosis in pulmonary position-a pilot study.Interact Cardiovasc Thorac Surg. 2022 Jul 9;35(2):ivac070. doi: 10.1093/icvts/ivac070. Interact Cardiovasc Thorac Surg. 2022. PMID: 35253872 Free PMC article.
-
DOACs in the Anticoagulation of Mechanical Valves: A Systematic Review and Future Perspectives.J Clin Med. 2023 Jul 28;12(15):4984. doi: 10.3390/jcm12154984. J Clin Med. 2023. PMID: 37568386 Free PMC article. Review.
-
Clinical and quality of life outcomes after aortic valve replacement and aortic root surgery in adult patients <65 years old.Ann Cardiothorac Surg. 2019 May;8(3):372-382. doi: 10.21037/acs.2019.04.07. Ann Cardiothorac Surg. 2019. PMID: 31240181 Free PMC article.
References
-
- Horstkotte D, Schulte HD, Bircks W, Strauer BE. Lower intensity anticoagulation therapy results in lower complication rates with the St. Jude Medical prosthesis. J Thorac Cardiovasc Surg. 1994;107:1136–1145. - PubMed
-
- Horstkotte D, Piper C. Improvement of oral anticoagulation therapy by INR self-management. J Heart Valve Dis. 2004;13:335–338. - PubMed
Publication types
MeSH terms
Substances
Associated data
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical