An unusual complication after placement of an inferior vena cava filter via right internal jugular vein access
- PMID: 29855215
- DOI: 10.1177/1129729818777967
An unusual complication after placement of an inferior vena cava filter via right internal jugular vein access
Abstract
Introduction:: Totally implantable venous access devices are used extensively worldwide in cancer patients for administration of venotoxic agents, blood sampling, and nutrition. Their tip is usually positioned at the junction of superior vena cava and right atrium. Inferior vena cava filters are usually used for deep venous thrombosis in cases where anticoagulation is contraindicated; they can be inserted either via internal jugular or femoral access depending on patient conditions and preference.
Case description:: We are describing here a case of totally implantable venous access device fracture following a right internal jugular approach for inferior vena cava filter placement as the patient had inferior vena cava thrombus below the renal veins, extending into the right common iliac vein prohibiting femoral approach.
Conclusion:: Iatrogenic fracture of totally implantable venous access device is a potential complication of accessing the internal jugular vein for other procedures such as insertion of inferior vena cava filter.
Keywords: Inferior vena cava filter; cancer; deep venous thrombosis; totally implantable venous access device.
Similar articles
-
Inferior vena cava thrombosis due to tunneled hemodialysis catheter inserted in the internal jugular vein.J Vasc Access. 2014 Jul-Aug;15(4):327-8. doi: 10.5301/jva.5000197. Epub 2014 Jan 15. J Vasc Access. 2014. PMID: 24474521 No abstract available.
-
Strategies for prevention of iatrogenic inferior vena cava filter entrapment and dislodgement during central venous catheter placement.J Vasc Surg. 2014 Jan;59(1):255-9. doi: 10.1016/j.jvs.2013.07.116. Epub 2013 Sep 29. J Vasc Surg. 2014. PMID: 24080132 Review.
-
Femoral versus jugular access for Denali Vena Cava Filter placement: Analysis of fluoroscopic time, filter tilt and retrieval outcomes.Clin Imaging. 2018 Nov-Dec;52:337-342. doi: 10.1016/j.clinimag.2018.09.008. Epub 2018 Sep 19. Clin Imaging. 2018. PMID: 30243205
-
Removal of a fractured tunneled cuffed catheter from the right atrium and inferior vena cava by percutaneous snare technique.J Vasc Access. 2016 May 7;17(3):e42-3. doi: 10.5301/jva.5000497. J Vasc Access. 2016. PMID: 26797903 No abstract available.
-
Greenfield inferior vena cava filter dislodged during central venous catheter placement.Chest. 1994 Sep;106(3):957-9. doi: 10.1378/chest.106.3.957. Chest. 1994. PMID: 8082390 Review.
Publication types