Can integrated 18F-FDG PET/MR replace sentinel lymph node resection in malignant melanoma?
- PMID: 29876618
- DOI: 10.1007/s00259-018-4061-9
Can integrated 18F-FDG PET/MR replace sentinel lymph node resection in malignant melanoma?
Abstract
Purpose: To compare the sensitivity and specificity of 18F-fluordesoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT), 18F-FDG PET/magnetic resonance (18F-FDG PET/MR) and 18F-FDG PET/MR including diffusion weighted imaging (DWI) in the detection of sentinel lymph node metastases in patients suffering from malignant melanoma.
Material & methods: Fifty-two patients with malignant melanoma (female: n = 30, male: n = 22, mean age 50.5 ± 16.0 years, mean tumor thickness 2.28 ± 1.97 mm) who underwent 18F-FDG PET/CT and subsequent PET/MR & DWI for distant metastasis staging were included in this retrospective study. After hybrid imaging, lymphoscintigraphy including single photon emission computed tomography/CT (SPECT/CT) was performed to identify the sentinel lymph node prior to sentinel lymph node biopsy (SLNB). In a total of 87 sentinel lymph nodes in 64 lymph node basins visible on SPECT/CT, 17 lymph node metastases were detected by histopathology. In separate sessions PET/CT, PET/MR, and PET/MR & DWI were assessed for sentinel lymph node metastases by two independent readers. Discrepant results were resolved in a consensus reading. Sensitivities, specificities, positive predictive values and negative predictive values were calculated with histopathology following SPECT/CT guided SLNB as a reference standard.
Results: Compared with histopathology, lymph nodes were true positive in three cases, true negative in 65 cases, false positive in three cases and false negative in 14 cases in PET/CT. PET/MR was true positive in four cases, true negative in 63 cases, false positive in two cases and false negative in 13 cases. Hence, we observed a sensitivity, specificity, positive predictive value and negative predictive value of 17.7, 95.6, 50.0 and 82.3% for PET/CT and 23.5, 96.9, 66.7 and 82.3% for PET/MR. In DWI, 56 sentinel lymph node basins could be analyzed. Here, the additional analysis of DWI led to two additional false positive findings, while the number of true positive findings could not be increased.
Conclusion: In conclusion, integrated 18F-FDG PET/MR does not reliably differentiate N-positive from N-negative melanoma patients. Additional DWI does not increase the sensitivity of 18F-FDG PET/MR. Hence, sentinel lymph node biopsy cannot be replaced by 18F-FDG-PE/MR or 18F-FDG-PET/CT.
Keywords: DWI; MM; MRI; Malignant melanoma; PET/CT; PET/MRI.
Similar articles
-
Diagnostic performance of 18F-FDG PET/CT and whole-body diffusion-weighted imaging with background body suppression (DWIBS) in detection of lymph node and bone metastases from pediatric neuroblastoma.Ann Nucl Med. 2018 Jun;32(5):348-362. doi: 10.1007/s12149-018-1254-z. Epub 2018 Apr 17. Ann Nucl Med. 2018. PMID: 29667143 Free PMC article.
-
Preoperative 18F-FDG-PET/CT imaging and sentinel node biopsy in the detection of regional lymph node metastases in malignant melanoma.Melanoma Res. 2008 Oct;18(5):346-52. doi: 10.1097/CMR.0b013e32830b363b. Melanoma Res. 2008. PMID: 18781133
-
18F-Fluorodeoxyglucose Positron Emission Tomography/Magnetic Resonance in Lymphoma: Comparison With 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography and With the Addition of Magnetic Resonance Diffusion-Weighted Imaging.Invest Radiol. 2016 Mar;51(3):163-9. doi: 10.1097/RLI.0000000000000218. Invest Radiol. 2016. PMID: 26784400 Free PMC article.
-
A critical reappraisal of false negative sentinel lymph node biopsy in melanoma.Q J Nucl Med Mol Imaging. 2014 Jun;58(2):105-13. Q J Nucl Med Mol Imaging. 2014. PMID: 24835287 Review.
-
18F-FDG PET/CT and whole-body MRI diagnostic performance in M staging for non-small cell lung cancer: a systematic review and meta-analysis.Eur Radiol. 2020 Jul;30(7):3641-3649. doi: 10.1007/s00330-020-06703-1. Epub 2020 Mar 3. Eur Radiol. 2020. PMID: 32125513
Cited by
-
Value of 18F-FDG Hybrid PET/MR in Differentiated Thyroid Cancer Patients with Negative 131I Whole-Body Scan and Elevated Thyroglobulin Levels.Cancer Manag Res. 2021 Mar 29;13:2869-2876. doi: 10.2147/CMAR.S293005. eCollection 2021. Cancer Manag Res. 2021. PMID: 33824601 Free PMC article.
-
Imaging of pediatric cutaneous melanoma.Pediatr Radiol. 2019 Oct;49(11):1476-1487. doi: 10.1007/s00247-019-04374-9. Epub 2019 Oct 16. Pediatr Radiol. 2019. PMID: 31620848 Free PMC article. Review.
-
Feasibility and impact of sentinel lymph node biopsy in patients affected by ano-rectal melanoma.Tech Coloproctol. 2025 Jan 3;29(1):38. doi: 10.1007/s10151-024-03086-z. Tech Coloproctol. 2025. PMID: 39751869
-
Diagnostic Performance of [18F]F-FDG Positron Emission Tomography (PET) in Non-Ophthalmic Malignant Melanoma: A Systematic Review and Meta-Analysis of More Than 10,000 Melanoma Patients.Cancers (Basel). 2024 Jan 2;16(1):215. doi: 10.3390/cancers16010215. Cancers (Basel). 2024. PMID: 38201642 Free PMC article. Review.
-
Precision Nuclear Medicine: The Evolving Role of PET in Melanoma.Radiol Clin North Am. 2021 Sep;59(5):755-772. doi: 10.1016/j.rcl.2021.05.007. Radiol Clin North Am. 2021. PMID: 34392917 Free PMC article. Review.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical