. 2018 May 8;15(2):663-665.
doi: 10.1016/j.jor.2018.05.045. eCollection 2018 Jun.

Supracondylar femur fracture repair using IlluminOss in a patient with Osteogenesis Imperfecta type 4

Affiliations

Supracondylar femur fracture repair using IlluminOss in a patient with Osteogenesis Imperfecta type 4

D Meijering et al. J Orthop. .

Erratum in

No abstract available

PubMed Disclaimer

Figures

None
Graphical abstract
Fig. 1
Fig. 1
In patient history after Xrays showed an supracondylar femur fracture right sided.
Fig. 2
Fig. 2
In procedure after: x-rays showed the right position of the implant.
Fig. 3
Fig. 3
In follow-up after The x-ray showed the femoral fracture with illuminoss implant.

References

    1. Antoniazzi F., Mottes M., Fraschini P., Brunelli P.C., Tato L. Osteogenesis imperfecta: practical treatment guidelines. Paediatr Drugs. 2000;2(6):465–488. - PubMed
    1. Jahangir A.A., Cross W., Schmidt A. Curr Manag Distal Femoral Fract. 2010;21(March/April (2)):193–197.
    1. Larsson S. Treatment of osteoporotic fractures. Scand J. 2002;91(2):140–146. - PubMed
    1. Ricci W.M., Loftus T., Cox C., Borrelli J. Locked plates combined with minimally invasive insertion technique for the treatment of periprosthetic supracondylar femur fractures above a total knee arthroplasty. J Orthop Trauma. 2006;20(3):190–196. - PubMed
    1. Vegt P., Muir J.M., Block J.E. The photodynamic bone stabilization system: a minimally invasive, percutaneous intramedullary polymeric osteosynthesis for simple and complex long bone fractures. Med Devices (Auckland, N.Z.) 2014;7:453–461. - PMC - PubMed