. 2020 Apr;29(4):341-349.
doi: 10.1111/jopr.12926. Epub 2018 Jun 13.

A Comparison of the Flexural and Impact Strengths and Flexural Modulus of CAD/CAM and Conventional Heat-Cured Polymethyl Methacrylate (PMMA)

Affiliations

A Comparison of the Flexural and Impact Strengths and Flexural Modulus of CAD/CAM and Conventional Heat-Cured Polymethyl Methacrylate (PMMA)

Ziad N Al-Dwairi et al. J Prosthodont. 2020 Apr.

Abstract

Purpose: The introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) technology to the field of removable prosthodontics has recently made it possible to fabricate complete dentures of prepolymerized polymethyl methacrylate (PMMA) blocks, which are claimed to be of better mechanical properties; however, no published reports that have evaluated mechanical properties of CAD/CAM PMMA. The purpose of this study was to compare flexural strength, impact strength, and flexural modulus of two brands of CAD/CAM PMMA and a conventional heat-cured PMMA.

Materials and methods: 45 rectangular specimens (65 mm × 10 mm × 3 mm) were fabricated (15 CAD/CAM AvaDent PMMA specimens from AvaDent, 15 CAD/CAM Tizian PMMA specimens from Shütz Dental, 15 conventional Meliodent PMMA specimens from Heraeus Kulzer) and stored in distilled water at (37 ± 1°C) for 7 days. Specimens (N = 15) in each group were subjected to the three-point bending test and impact strength test, employing the Charpy configuration on unnotched specimens. The morphology of the fractured specimens was studied under a scanning electron microscope (SEM). Statistical analysis was performed using one-way ANOVA and Tukey pairwise multiple comparisons with 95% confidence interval.

Results: The Schütz Dental specimens showed the highest mean flexural strength (130.67 MPa) and impact strength (29.56 kg/m2 ). The highest mean flexural modulus was recorded in the AvaDent group (2519.6 MPa). The conventional heat-cured group showed the lowest mean flexural strength (93.33 MPa), impact strength (14.756 kg/m2 ), and flexural modulus (2117.2 MPa). Differences in means of flexural properties between AvaDent and Schütz Dental specimens were not statistically significant (p > 0.05).

Conclusions: As CAD/CAM PMMA specimens exhibited improved flexural strength, flexural modulus, and impact strength in comparison to the conventional heat-cured groups, CAD/CAM dentures are expected to be more durable. Different brands of CAD/CAM PMMA may have inherent variations in mechanical properties.

Keywords: CAD/CAM; flexural strength; impact strength.

PubMed Disclaimer

References

    1. Kanazawa M, Inokoshi M, Minakuchi S, et al: Trial of a CAD/CAM system for fabricating complete dentures. Dent Mater J 2011;30:93-96
    1. Mahross HZ, Mohamed MD, Hassan AM, et al: Effect of cigarette smoke on surface roughness of different denture base materials. J Clin Diagn Res 2015;9:39-42
    1. Lee HH, Lee CJ, Asaoka K: Correlation in the mechanical properties of acrylic denture base resins. Dent Mater J 2012;31:157-164
    1. Farina AP, Cecchin D, Soares RG, et al: Evaluation of Vickers hardness of different types of acrylic denture base resins with and without glass fibre reinforcement. Gerodontology 2012;29:155-160
    1. Takahashi Y, Yoshida K, Shimizu H: Fracture resistance of maxillary complete dentures subjected to long-term water immersion. Gerodontology 2012;29:1086-1091

LinkOut - more resources