Association of cardiac implantable electronic devices with survival in bifascicular block and prolonged PR interval on electrocardiogram

Affiliations
Comparative Study

Association of cardiac implantable electronic devices with survival in bifascicular block and prolonged PR interval on electrocardiogram

Naeem Moulki et al. J Interv Card Electrophysiol. 2018 Aug.

Abstract

Purpose: Bifascicular block and prolonged PR interval on the electrocardiogram (ECG) have been associated with complete heart block and sudden cardiac death. We sought to determine if cardiac implantable electronic devices (CIED) improve survival in these patients.

Methods: We assessed survival in relation to CIED status among 636 consecutive patients with bifascicular block and prolonged PR interval on the ECG. In survival analyses, CIED was considered as a time-varying covariate.

Results: Average age was 76 ± 9 years, and 99% of the patients were men. A total of 167 (26%) underwent CIED (127 pacemaker only) implantation at baseline (n = 23) or during follow-up (n = 144). During 5.4 ± 3.8 years of follow-up, 83 (13%) patients developed complete or high-degree atrioventricular block and 375 (59%) died. Patients with a CIED had a longer survival compared to those without a CIED in the traditional, static analysis (log-rank p < 0.0001) but not when CIED was considered as a time-varying covariate (log-rank p = 0.76). In the multivariable model, patients with a CIED had a 34% lower risk of death (hazard ratio 0.66, 95% confidence interval 0.52-0.83; p = 0.001) than those without CIED in the traditional analysis but not in the time-varying covariate analysis (hazard ratio 1.05, 95% confidence interval 0.79-1.38; p = 0.76). Results did not change in the subgroup with a pacemaker only.

Conclusions: Bifascicular block and prolonged PR interval on ECG are associated with a high incidence of complete atrioventricular block and mortality. However, CIED implantation does not have a significant influence on survival when time-varying nature of CIED implantation is considered.

Keywords: Atrioventricular block; Bifascicular block; Cardiac implantable electronic device; Pacemaker; Survival.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Europace. 2013 Aug;15(8):1070-118 - PubMed
    1. Stat Med. 1984 Jan-Mar;3(1):35-44 - PubMed
    1. N Engl J Med. 1982 Jul 15;307(3):137-43 - PubMed
    1. Am J Gastroenterol. 2015 Dec;110(12):1647-50 - PubMed
    1. Am J Med. 1973 Mar;54(3):297-303 - PubMed

Publication types

MeSH terms

LinkOut - more resources