Quantification of bone microstructure in the wrist using cone-beam computed tomography
- PMID: 29909060
- DOI: 10.1016/j.bone.2018.06.006
Quantification of bone microstructure in the wrist using cone-beam computed tomography
Abstract
Due to the rising life expectancy, bone diseases (e.g. osteoporosis, osteoarthritis) and trauma (e.g. fracture) have become an important socio-economic burden. Accurate visualization and quantification of the bone microstructure in vivo is seen as an important step to enhance diagnosis and treatment. Micro-computed tomography (microCT) has become the gold standard in three-dimensional (3D) imaging of trabecular bone structure. Yet, usage is limited to ex vivo analyses, hence, it cannot be used to evaluate bone and bone adaptive responses in a patient. High-resolution peripheral computed tomography (HR-pQCT) is considered the best technique to measure the bone microarchitecture in vivo. By design HR-pQCT is limited to scanning extremities, such as the distal radius and distal tibia with a limited field of view and long scanning time (~2 à 3 min. for a stack of 0.9 cm). Cone-beam computed tomography (CBCT) is a promising alternative with a much larger field of view. Yet, CBCT is challenged by artefacts that reduce image contrast, such that it is currently being used for qualitative evaluation only. Therefore, the aims of this work were first to enhance image contrast and second to determine the accuracy of high-resolution CBCT for bone microarchitectural assessment. Trapezia of nineteen female arthritic patients were scanned twice ex vivo; once using CBCT (NewTom 5G, Cefla, Verona, Italy) at a nominal voxel size of 75 μm and once using microCT (SkyScan 1172, Bruker, Kontich, Belgium) at a voxel size of 19.84 μm. The CBCT-scans were reconstructed following 2 protocols: (1) using the commercial software delivered with the scanner and (2) using in-house developed software. After reconstruction and image processing, the images were segmented using adaptive thresholding. Bone morphometric parameters including bone volume (BV), total tissue volume (TV), bone volume fraction (BV/TV), bone surface density (BS/TV), trabecular thickness (Tb.Th), trabecular separation (Tb.Sp) and trabecular number (Tb.N) were calculated. Statistical evaluations were made at a significance level of 5%. Significant correlations were found between the CBCT-based bone parameters and the microCT-based parameters with R2 > 0.68 The in-house reconstructed software outperformed the commercial software. Smaller bias (overestimation of Tb.Th decreased from 114.24% to 59.96%) as well as higher correlations were observed for the in-house processed images. Still, a significant overestimation was observed for BV/TV and Tb. Th and an underestimation for Tb.N. We conclude that our CBCT image reconstruction improved image contrast which allowed for an accurate quantification of trabecular bone microarchitecture.
Keywords: Bone parameters; Cone-beam computed tomography; Medical imaging processing; Micro-computed tomography; Quantification.
Copyright © 2018 Elsevier Inc. All rights reserved.
Similar articles
-
Correlation Between Cone-Beam Computed Tomography and High-Resolution Peripheral Computed Tomography for Assessment of Wrist Bone Microstructure.J Bone Miner Res. 2019 May;34(5):867-874. doi: 10.1002/jbmr.3673. Epub 2019 Mar 26. J Bone Miner Res. 2019. PMID: 30912861
-
High-Resolution Cone-Beam Computed Tomography is a Fast and Promising Technique to Quantify Bone Microstructure and Mechanics of the Distal Radius.Calcif Tissue Int. 2021 Mar;108(3):314-323. doi: 10.1007/s00223-020-00773-5. Epub 2021 Jan 16. Calcif Tissue Int. 2021. PMID: 33452889
-
Accuracy and precision of segmentation and quantification of wrist bone microarchitecture using photon-counting computed tomography ex vivo.Bone. 2025 May;194:117443. doi: 10.1016/j.bone.2025.117443. Epub 2025 Mar 1. Bone. 2025. PMID: 40032018
-
CBCT-based bone quality assessment: are Hounsfield units applicable?Dentomaxillofac Radiol. 2015;44(1):20140238. doi: 10.1259/dmfr.20140238. Dentomaxillofac Radiol. 2015. PMID: 25315442 Free PMC article. Review.
-
Guidelines for assessment of bone microstructure in rodents using micro-computed tomography.J Bone Miner Res. 2010 Jul;25(7):1468-86. doi: 10.1002/jbmr.141. J Bone Miner Res. 2010. PMID: 20533309 Review.
Cited by
-
Effect of Bone Microstructure Derived From CBCT on the Accuracy of Robot-Assisted Implant Surgery: A Retrospective Study.Clin Oral Implants Res. 2025 Jun;36(6):673-682. doi: 10.1111/clr.14414. Epub 2025 Feb 6. Clin Oral Implants Res. 2025. PMID: 39912590 Free PMC article.
-
A Drug Holiday Reduces the Frequency and Severity of Medication-Related Osteonecrosis of the Jaw in a Minipig Model.J Bone Miner Res. 2020 Nov;35(11):2179-2192. doi: 10.1002/jbmr.4119. Epub 2020 Aug 10. J Bone Miner Res. 2020. PMID: 32568416 Free PMC article.
-
Photon-Counting Computed Tomography for Microstructural Imaging of Bone and Joints.Curr Osteoporos Rep. 2024 Aug;22(4):387-395. doi: 10.1007/s11914-024-00876-0. Epub 2024 Jun 4. Curr Osteoporos Rep. 2024. PMID: 38833188 Review.
-
The Role of Cone-Beam Computed Tomography CT Extremity Arthrography in the Preoperative Assessment of Osteoarthritis.Tomography. 2023 Nov 29;9(6):2134-2147. doi: 10.3390/tomography9060167. Tomography. 2023. PMID: 38133071 Free PMC article.
-
Automated bone property analysis using corrected in vivo dental cone-beam CT data of human wrists.Sci Rep. 2024 Dec 16;14(1):30466. doi: 10.1038/s41598-024-75222-6. Sci Rep. 2024. PMID: 39681574 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical