Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2018 Jul;6(4):517-522.e1.
doi: 10.1016/j.jvsv.2018.02.005.

Hemodynamics of venous valve pairing and implications on helical flow

Affiliations
Free article

Hemodynamics of venous valve pairing and implications on helical flow

Henry Y Chen et al. J Vasc Surg Venous Lymphat Disord. 2018 Jul.
Free article

Abstract

Background: It has been shown that venous valves have pairing arrangements with specific relative orientation and spacing that contribute to helical flows. The studies to date have not quantified the hemodynamic impact of helical flow formation. A computational model allows various valve orientations and spacings to be studied to better understand the hemodynamic effect of valve pairing.

Methods: Simulations were performed for paired valves at physiologically relevant spacing and orientations to study the flow features and hemodynamics associated with valve pairing configurations. The wall shear stress (WSS), residence time, and pressure drop were evaluated for the various valve pairing cases.

Results: It was found that the WSS on the lumen flow side (front) of the leaflet is several times higher than on the valve pocket side (back). With orthogonal paired valves, the WSS at the critical back side is increased. Helical flow was clearly observed only with orthogonal valve pairing. The residence time was reduced to less than half (0.47 vs 1.16 seconds) in the orthogonal valve case compared with the parallel valve cases. The farther spaced valves (6 cm) had the highest residence time.

Conclusions: This simulation study shows that helical flow in the veins of lower extremities is strongly dependent on the relative orientation and spacing of the valves. For optimal orientation (∼90 degrees) and spacing (∼4 cm), strong helical flow is seen, which enhances WSS and reduces the flow resistance and residence time. These findings demonstrate a structure-function relation that optimizes flow patterns in normal physiology, which can be compromised in venous valve disease. The results of this study provide valuable insights that improve the current understanding of blood flow patterns around venous valves and the design of future multiple paired prosthetic valves.

Keywords: Fluid-structure interaction; Residence time; Valve pairing; Wall shear stress.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources