Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1985 Aug;6(2):349-58.
doi: 10.1016/s0735-1097(85)80171-6.

Tomographic gated blood pool radionuclide ventriculography: analysis of wall motion and left ventricular volumes in patients with coronary artery disease

Free article
Comparative Study

Tomographic gated blood pool radionuclide ventriculography: analysis of wall motion and left ventricular volumes in patients with coronary artery disease

J R Corbett et al. J Am Coll Cardiol. 1985 Aug.
Free article

Abstract

The use of planar radionuclide ventriculography to evaluate global and segmental ventricular function is limited by the superimposition of structures in some projections and the gross segmental resolution of the planar technique. Preliminary reports have suggested the feasibility of tomographic gated radionuclide ventriculography with rotating detector systems. This study tested the hypotheses that 1) tomographic radionuclide ventriculography detects segmental dysfunction at rest not identified with multiview planar studies and single plane contrast ventriculography, and 2) ventricular volumes and ejection fraction calculated from these studies provide data similar to those obtained with angiography and planar radionuclide ventriculography. Gated blood pool tomograms were acquired over 180 degrees at 15 frames per cardiac cycle during the initial 90% of the cardiac cycle. Compared with the multiview planar technique tomographic ventriculography showed an increased sensitivity for detecting left ventricular segments with significant coronary artery stenosis (97 versus 74%, p less than 0.025) without any loss in specificity. Compared with both planar radionuclide and contrast ventriculography, tomographic radionuclide ventriculography also detected more noninfarcted left ventricular segments supplied by stenosed coronary arteries (81 versus 39 and 32%, respectively, p less than 0.01). Tomographic radionuclide ventriculographic measurements of left ventricular volumes and ejection fraction showed close correlations with angiographic and planar radionuclide determinations. Gated blood pool tomography is a sensitive method for the evaluation of segmental wall motion and an accurate method for the measurement of global left ventricular volumes and ejection fraction.

PubMed Disclaimer

Similar articles

Cited by

Publication types

Substances

LinkOut - more resources