. 2018 Aug;113(8):1238-1246.
doi: 10.1038/s41395-018-0143-3. Epub 2018 Jun 19.

Office-Based Point of Care Testing (IgA/IgG-Deamidated Gliadin Peptide) for Celiac Disease

Affiliations

Office-Based Point of Care Testing (IgA/IgG-Deamidated Gliadin Peptide) for Celiac Disease

Michelle S Lau et al. Am J Gastroenterol. 2018 Aug.

Abstract

Objectives: Celiac disease (CD) is common yet under-detected. A point of care test (POCT) may improve CD detection. We aimed to assess the diagnostic performance of an IgA/IgG-deamidated gliadin peptide (DGP)-based POCT for CD detection, patient acceptability, and inter-observer variability of the POCT results.

Methods: From 2013-2017, we prospectively recruited patients referred to secondary care with gastrointestinal symptoms, anemia and/or weight loss (group 1); and patients with self-reported gluten sensitivity with unknown CD status (group 2). All patients had concurrent POCT, IgA-tissue transglutaminase (IgA-TTG), IgA-endomysial antibodies (IgA-EMA), total IgA levels, and duodenal biopsies. Five hundred patients completed acceptability questionnaires, and inter-observer variability of the POCT results was compared among five clinical staff for 400 cases.

Results: Group 1: 1000 patients, 58.5% female, age 16-91, median age 57. Forty-one patients (4.1%) were diagnosed with CD. The sensitivities of the POCT, IgA-TTG, and IgA-EMA were 82.9, 78.1, and 70.7%; the specificities were 85.4, 96.3, and 99.8%. Group 2: 61 patients, 83% female; age 17-73, median age 35. The POCT had 100% sensitivity and negative predictive value in detecting CD in group 2. Most patients preferred the POCT to venepuncture (90.4% vs. 2.8%). There was good inter-observer agreement on the POCT results with a Fleiss Kappa coefficient of 0.895.

Conclusions: The POCT had comparable sensitivities to serology, and correctly identified all CD cases in a gluten sensitive cohort. However, its low specificity may increase unnecessary investigations. Despite its advantage of convenience and rapid results, it may not add significant value to case finding in an office-based setting.

PubMed Disclaimer

Similar articles

Cited by

Publication types