Anti-HTLV-III testing of blood donors: reproducibility and confirmability of commercial test kits
- PMID: 2992129
- DOI: 10.1046/j.1537-2995.1985.25485273826.x
Anti-HTLV-III testing of blood donors: reproducibility and confirmability of commercial test kits
Abstract
Since 2% of the cases of Acquired Immune Deficiency Syndrome (AIDS) have been attributed to transfusions of blood and blood products, licensed tests to detect antibody to the human T-lymphotropic virus type III (anti-HTLV-III) have been put into practice to reduce the risk of transfusion associated AIDS. Two commercial ELISA kits (Abbott and ENI) were used to test for anti-HTLV-III in 100 coded samples from individuals with AIDS, at high risk for AIDS, or with low risk for AIDS and in 1280 unlinked blood donor serums. From the 100 coded samples, both Abbott and ENI tests identified 51 of 52 coded samples with anti-HTLV-III which were confirmable with Western blot analysis. Initial testing of the donor serums by Abbott's test revealed 20 reactives, of which 5 were repeatably reactive; initial testing by ENI's test revealed 25 reactives, of which 14 were repeatably reactive. However, only 3 donor serums were repeatably reactive by both test kits, out of 17 repeatable reactive by either, and no ELISA positive samples were confirmed by Western blot or IFA. Before a blood donor is notified of "anti-HTLV-III reactivity", tests demonstrating this should be both reproducible and confirmable by at least one additional test.
Similar articles
-
Performance evaluation of the Abbott HTLV III EIA, a test for antibody to HTLV III in donor blood.Am J Clin Pathol. 1986 Aug;86(2):180-5. doi: 10.1093/ajcp/86.2.180. Am J Clin Pathol. 1986. PMID: 3017089
-
Importance of western blot analysis in predicting infectivity of anti-HTLV-III/LAV positive blood.Lancet. 1985 Nov 16;2(8464):1083-6. doi: 10.1016/s0140-6736(85)90683-x. Lancet. 1985. PMID: 2865566
-
Determination of antibodies against LAV/HTLV III: comparative evaluation of four different commercial test kits.AIDS Res. 1986 Spring;2(2):93-7. doi: 10.1089/aid.1.1986.2.93. AIDS Res. 1986. PMID: 3013224
-
Decision analysis of the HTLV-III screening test for blood donors.AIDS Res. 1986 Feb;2(1):5-17. doi: 10.1089/aid.1.1986.2.5. AIDS Res. 1986. PMID: 3013219
-
Anti-HTLV-III screening of blood donors.Vox Sang. 1986;51 Suppl 1:15-20. doi: 10.1111/j.1423-0410.1986.tb01988.x. Vox Sang. 1986. PMID: 3017001
Cited by
-
Significance of quantitative enzyme-linked immunosorbent assay (ELISA) results in evaluation of three ELISAs and Western blot tests for detection of antibodies to human immunodeficiency virus in a high-risk population.J Clin Microbiol. 1987 Feb;25(2):395-400. doi: 10.1128/jcm.25.2.395-400.1987. J Clin Microbiol. 1987. PMID: 3546369 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical