Medium- to Long-Term Results of the Nexgen Legacy Posterior Stabilized Fixed-Bearing Knee Replacement
- PMID: 29925103
- DOI: 10.1055/s-0038-1660477
Medium- to Long-Term Results of the Nexgen Legacy Posterior Stabilized Fixed-Bearing Knee Replacement
Abstract
The NexGen legacy posterior stabilized (LPS) prosthesis was introduced in 1997 after many design changes to its predecessor, the Insall-Burstein II prosthesis. However, there have been no reported long-term studies on the performance of this implant. Prospectively, collected data from a local database comprising primary total knee replacements (TKRs) with LPS between 1997 and 2002 was analyzed. All implants were fixed with cement. Patients were followed up at 1, 3, 5, 7, and 10 years, with patient satisfaction, range of movement, and Knee Society score (KSS) assessed. A total of 621 primary TKRs were analyzed with an average follow-up of 11.25 years (9.15-14.55). The mean age was 69.53 years. The mean KSS was 88.97 and mean flexion increased from 88.3 to 103.5 degrees at 10 years. Kaplan-Meier's analysis revealed a survivorship of 96.5% with revision for any reason as the end point and 98.9% if aseptic loosening was the reason for revision at 14 years. This study revealed excellent mid- to long-term results with the NexGen LPS prosthesis.
Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Conflict of interest statement
None declared.
Similar articles
-
High-flexion total knee arthroplasty: survivorship and prevalence of osteolysis: results after a minimum of ten years of follow-up.J Bone Joint Surg Am. 2012 Aug 1;94(15):1378-84. doi: 10.2106/JBJS.K.01229. J Bone Joint Surg Am. 2012. PMID: 22854990
-
The rates of osteolysis and loosening associated with a modular posterior stabilized knee replacement. Results at five to fourteen years.J Bone Joint Surg Am. 2004 Mar;86(3):525-30. doi: 10.2106/00004623-200403000-00010. J Bone Joint Surg Am. 2004. PMID: 14996878
-
[10-Year Follow-Up of the NexGen CR Total Knee Prosthesis].Z Orthop Unfall. 2015 Oct;153(5):508-15. doi: 10.1055/s-0035-1546040. Epub 2015 May 20. Z Orthop Unfall. 2015. PMID: 25993350 Clinical Trial. German.
-
The outcome of rotating-platform total knee arthroplasty with cement at a minimum of ten years of follow-up.J Bone Joint Surg Am. 2012 Apr 4;94(7):638-44. doi: 10.2106/JBJS.K.00263. J Bone Joint Surg Am. 2012. PMID: 22488620
-
Patients achieved greater range of movement when using high-flexion implants.Knee Surg Sports Traumatol Arthrosc. 2015 Jun;23(6):1598-609. doi: 10.1007/s00167-014-3314-9. Epub 2014 Oct 10. Knee Surg Sports Traumatol Arthrosc. 2015. PMID: 25300361 Review.
Cited by
-
Serial changes in patient-reported outcome measures and satisfaction rate during long-term follow-up after total knee arthroplasty: a systematic review and meta-analysis.Knee Surg Relat Res. 2024 Dec 4;36(1):43. doi: 10.1186/s43019-024-00241-6. Knee Surg Relat Res. 2024. PMID: 39633483 Free PMC article. Review.
-
Long-term outcomes of the Nexgen© posterior stabilized knee: minimum 15 year follow-safe and effective.Eur J Orthop Surg Traumatol. 2023 Oct;33(7):2943-2949. doi: 10.1007/s00590-023-03514-0. Epub 2023 Mar 13. Eur J Orthop Surg Traumatol. 2023. PMID: 36912950 Free PMC article.
-
Effect of material selection on tibial post stresses in posterior-stabilized knee prosthesis.Bone Joint Res. 2020 Nov;9(11):768-777. doi: 10.1302/2046-3758.911.BJR-2020-0019.R2. Bone Joint Res. 2020. PMID: 33135462 Free PMC article.
-
Early Clinical Outcomes (ECO) in the Era of Rapid Recovery Total Joint Arthroplasty: A Comparative Evaluation of Three Bearing Surfaces.Cureus. 2025 Feb 2;17(2):e78398. doi: 10.7759/cureus.78398. eCollection 2025 Feb. Cureus. 2025. PMID: 40046351 Free PMC article.