Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Case Reports
. 2018 May 24;9(2):264-268.
doi: 10.1159/000488849. eCollection 2018 May-Aug.

Cataract Surgery following Sequential Myopic and Hyperopic LASIK

Affiliations
Case Reports

Cataract Surgery following Sequential Myopic and Hyperopic LASIK

Tao Ming Thomas Chia et al. Case Rep Ophthalmol. .

Abstract

We report a case of patient dissatisfaction after sequential myopic and hyperopic LASIK in the same eye. We discuss the course of management for this patient involving eventual cataract extraction and intraocular lens (IOL) implantation with attention to the IOL power calculation method used.

Keywords: Formula; Intraocular lens power calculation; Patient dissatisfaction; Post-hyperopic LASIK intraocular lens calculation.

PubMed Disclaimer

Figures

Fig. 1.
Fig. 1.
Preoperative corneal topography of the right eye (left side of image) and the left eye (right side of image).
Fig. 2.
Fig. 2.
Anterior segment OCT revealing prior LASIK flap creation in the left eye.
Fig. 3.
Fig. 3.
Preoperative biometry with recommended intraocular lens calculations.
Fig. 4.
Fig. 4.
ASCRS post-hyperopic ablation intraocular lens recommendations with no clinical history.

References

    1. Fram NR, Masket S, Wang L. Comparison of Intraoperative Aberrometry OCT-Based IOL Formula and Masket Formulae for IOL Power Calculation after Laser Vision Correction. Ophthalmology. 2015 Jun;122((6)):1096–101. - PubMed
    1. Huang D, Tang M, Wang L, Zhang X, Armour RL, Gattey DM, et al. Optical coherence tomography-based corneal power measurement and intraocular lens power calculation following laser vision correction (an American Ophthalmological Society thesis) Trans Am Ophthalmol Soc. 2013 Sep;111:34–45. - PMC - PubMed
    1. Kwitko S, Marinho DR, Rymer S, Severo N, Arce CG. Orbscan II and double-K method for IOL calculation after refractive surgery. Graefes Arch Clin Exp Ophthalmol. 2012 Jul;250((7)):1029–34. - PubMed
    1. Wang L, Tang M, Huang D, Weikert MP, Koch DD. Comparison of Newer Intraocular Lens Power Calculation Methods for Eyes after Corneal Refractive Surgery. Ophthalmology. 2015 Dec;122((12)):2443–9. - PMC - PubMed
    1. Shammas HJ, Shammas MC, Garabet A, Kim JH, Shammas A, LaBree L. Correcting the corneal power measurements for intraocular lens power calculations after myopic laser in situ keratomileusis. Am J Ophthalmol. 2003 Sep;136((3)):426–32. - PubMed

Publication types

LinkOut - more resources