Emission tomography with 99mTc-pyrophosphate in the diagnosis of acute myocardial infarction
- PMID: 2992989
- DOI: 10.1007/BF00252739
Emission tomography with 99mTc-pyrophosphate in the diagnosis of acute myocardial infarction
Abstract
Electrocardiograms (ECG) and enzyme criteria are usually used to confirm the diagnosis of acute myocardial infarction in the case of chest pain. However, ECG is not always diagnostic. Elevated enzyme values may be due to causes other than myocardial infarction. In uncertain cases, the ECG and enzyme criteria can be supplemented by emission tomography, performed with technetium pyrophosphate that will accumulate in the site of infarction. Twenty-nine patients with suspected acute myocardial infarction were studied with emission tomography. Of these 12 had acute transmural infarction. Both enzyme tests and ECG were diagnostic in only 7 of these 12 cases, 4 had positive enzyme tests but a nondiagnostic ECG and in one case neither enzymes nor ECG were diagnostic. In 11 patients the infarcted myocardial area was detected with emission tomography. Six patients had acute nontransmural infarction. Only 2 of these had positive emission tomography. The chest pain was not due to infarction in 11 patients. All these patients had negative emission tomography. The sensitivity of emission tomography was 92% and specificity 100% in transmural acute infarction. In nontransmural infarction the specificity was only 33%. Emission tomography is a valuable diagnostic tool. It may be the decisive method when ECG and enzymes are not diagnostic. Emission tomography also shows the localization and size of the infarcted area in the myocardium.
Similar articles
-
Technetium-99m pyrophosphate tomogram of nontransmural myocardial infarction: a case report.Ann Nucl Med. 1988 Nov;2(2):85-8. doi: 10.1007/BF03164950. Ann Nucl Med. 1988. PMID: 2856318
-
99mTc-pyrophosphate imaging in patients with acute myocardial infarction: comparison of planar imaging with single-photon tomography with and without blood pool overlay.Circulation. 1984 Jun;69(6):1120-8. doi: 10.1161/01.cir.69.6.1120. Circulation. 1984. PMID: 6325039
-
Efficacy of technetium Tc 99m pyrophosphate imaging in patients with equivocal myocardial infarction.South Med J. 1983 Mar;76(3):338-40. doi: 10.1097/00007611-198303000-00018. South Med J. 1983. PMID: 6298947
-
Thallium-201 versus technetium-99m pyrophosphate myocardial imaging in detection and evaluation of patients with acute myocardial infarction.Am J Cardiol. 1980 Dec 18;46(7):1215-23. doi: 10.1016/0002-9149(80)90291-x. Am J Cardiol. 1980. PMID: 7006365 Review.
-
[Methods of determining the extent of a myocardial infarct].Sov Med. 1983;(1):52-5. Sov Med. 1983. PMID: 6301075 Review. Russian. No abstract available.
References
MeSH terms
Substances
LinkOut - more resources
Medical