Current State of Image Guidance in Radiation Oncology: Implications for PTV Margin Expansion and Adaptive Therapy
- PMID: 29933883
- DOI: 10.1016/j.semradonc.2018.02.008
Current State of Image Guidance in Radiation Oncology: Implications for PTV Margin Expansion and Adaptive Therapy
Abstract
Image guidance technology has evolved and seen widespread application in the past several decades. Advancements in the diagnostic imaging field have found new applications in radiation oncology and promoted the development of therapeutic devices with advanced imaging capabilities. A recent example is the development of linear accelerators that offer magnetic resonance imaging for real-time imaging and online adaptive planning. Volumetric imaging, in particular, offers more precise localization of soft tissue targets and critical organs which reduces setup uncertainty and permit the use of smaller setup margins. We present a review of the status of current imaging modalities available for radiation oncology and its impact on target margins and use for adaptive therapy.
Copyright © 2018 Elsevier Inc. All rights reserved.
Similar articles
-
Accounting for, Mitigating, and Choice of Margins for Moving Tumors.Semin Radiat Oncol. 2018 Jun;28(3):194-200. doi: 10.1016/j.semradonc.2018.02.004. Semin Radiat Oncol. 2018. PMID: 29933879 Review.
-
Evaluation of online/offline image guidance/adaptation approaches for prostate cancer radiation therapy.Int J Radiat Oncol Biol Phys. 2015 Apr 1;91(5):1026-33. doi: 10.1016/j.ijrobp.2014.12.043. Int J Radiat Oncol Biol Phys. 2015. PMID: 25832693
-
The Role of Optical Surface Imaging Systems in Radiation Therapy.Semin Radiat Oncol. 2018 Jun;28(3):185-193. doi: 10.1016/j.semradonc.2018.02.003. Semin Radiat Oncol. 2018. PMID: 29933878 Review.
-
Margins and Uncertainties in Radiation Oncology.Semin Radiat Oncol. 2018 Jun;28(3):169-170. doi: 10.1016/j.semradonc.2018.03.001. Semin Radiat Oncol. 2018. PMID: 29933875 No abstract available.
-
Magnetic Resonance Imaging for Target Delineation and Daily Treatment Modification.Semin Radiat Oncol. 2018 Jun;28(3):178-184. doi: 10.1016/j.semradonc.2018.02.002. Semin Radiat Oncol. 2018. PMID: 29933877 Review.
Cited by
-
Medical physics challenges in clinical MR-guided radiotherapy.Radiat Oncol. 2020 May 5;15(1):93. doi: 10.1186/s13014-020-01524-4. Radiat Oncol. 2020. PMID: 32370788 Free PMC article. Review.
-
Estimation of planning organ at risk volumes for ocular structures in dogs undergoing three-dimensional image-guided periocular radiotherapy with rigid bite block immobilization.Vet Radiol Ultrasound. 2021 Mar;62(2):246-254. doi: 10.1111/vru.12955. Epub 2021 Jan 18. Vet Radiol Ultrasound. 2021. PMID: 33460237 Free PMC article.
-
Development and evaluation of ultrasound image tracking technology based on Mask R-CNN applied to respiratory motion compensation system.Quant Imaging Med Surg. 2023 Oct 1;13(10):6827-6839. doi: 10.21037/qims-23-23. Epub 2023 Sep 5. Quant Imaging Med Surg. 2023. PMID: 37869357 Free PMC article.
-
Gadoxetic Acid Uptake Rate as a Measure of Global and Regional Liver Function as Compared With Indocyanine Green Retention, Albumin-Bilirubin Score, and Portal Venous Perfusion.Adv Radiat Oncol. 2022 Mar 16;7(5):100942. doi: 10.1016/j.adro.2022.100942. eCollection 2022 Sep-Oct. Adv Radiat Oncol. 2022. PMID: 35496263 Free PMC article.
-
Adaptive proton therapy.Phys Med Biol. 2021 Nov 15;66(22):10.1088/1361-6560/ac344f. doi: 10.1088/1361-6560/ac344f. Phys Med Biol. 2021. PMID: 34710858 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous