Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2019 Apr;59(2):235-242.
doi: 10.1111/ajo.12828. Epub 2018 Jun 26.

Foley catheter silicone versus latex for term outpatient induction of labour: A randomised trial

Affiliations
Randomized Controlled Trial

Foley catheter silicone versus latex for term outpatient induction of labour: A randomised trial

Therese M McGee et al. Aust N Z J Obstet Gynaecol. 2019 Apr.

Abstract

Background: Both silicone and latex single-balloon Foley catheters are available for cervical ripening but no literature exists to compare them. Local experience suggested more frequent insertion-related accidental rupture of the membranes (acROM) with silicone.

Aims: To compare the performance of silicone versus latex catheters with respect to acROM and other outcomes.

Materials and methods: Women undergoing outpatient Foley catheter cervical ripening were randomised to a silicone or latex catheter. Data were collected on the primary outcome, acROM, and secondary outcomes including catheter insertion failure, unplanned hospital admission and patient-reported discomfort, together with intrapartum fever and antibiotics for suspected chorioamnionitis along with general obstetric and neonatal outcomes.

Results: Among 534 recruited women, acROM was significantly more common with a silicone compared to a latex catheter at 7.2% (19/265) versus 1.5% (4/269) (relative risk (RR) 4.8; 95% CI 1.7-14.0). Insertion failure was significantly less common with silicone than latex at 2.6% (7/265) versus 9.3% (25/269) (RR 0.3; 95% CI 0.1-0.6). However, when the alternative catheter was subsequently tried, the final failure rates were 1.9% silicone (5/265) versus 2.6% latex (7/269). Insertion-related hospital admission was higher with silicone at 9.4% (25/265) than latex at 4.8% (13/269) (RR 2.1; 95% CI 1.1-4.1). All other obstetric outcomes were similar between the groups.

Conclusion: When used for cervical ripening, a silicone Foley catheter is associated with a higher rate of acROM than a latex catheter but a lower rate of insertion failure. It may, therefore, be reasonable to attempt insertion with a latex catheter initially and manage insertion failures with a silicone catheter.

Keywords: Foley catheter; accidental membrane rupture; cervical ripening; failed catheter insertion; labour induction.

PubMed Disclaimer

Publication types

LinkOut - more resources