Obstructive sleep apnea and the effect of CPAP treatment on ischemia-modified albumin levels: a multi effect size meta-analysis with diagnostic test accuracy
- PMID: 29948857
- DOI: 10.1007/s11325-018-1679-6
Obstructive sleep apnea and the effect of CPAP treatment on ischemia-modified albumin levels: a multi effect size meta-analysis with diagnostic test accuracy
Abstract
Purpose: A close association of oxidative stress (OS) and ischemia-modified albumin (IMA) with obstructive sleep apnea (OSA) has been reported in the literature, but the results on IMA are ambiguous. We conducted a meta-analysis to evaluate the association of IMA with OSA and the effect of continuous positive airway pressure (CPAP) therapy on IMA in patients with OSA.
Methods: Relevant studies were identified by searching PubMed and other databases in addition to manual searching of cross-references. Using random-effects model, the standardized mean differences (SMDs), pooled correlation coefficients and summary of diagnostic test accuracies were obtained with 95% confidence intervals (CIs). The meta-regression, sub-group and sensitivity analyses were performed to explore heterogeneity. The presence of publication bias was tested using funnel plot analysis followed by Begg's and Egger's tests for statistical signidicance.
Results: This meta-analysis finally included nine studies. When comparing with non-OSA controls, the OSA patients showed a significantly increased circulatory IMA levels (SMD = 1.15, p = 0.0001). And, this increase is even more pronounced in severe-OSA group as compared to mild-moderate OSA patients (SMD = 076, p = 0.0006). A decrease in post-CPAP treatment IMA was observed when compared with that of baseline values. Meta-analysis of correlations showed significant associations of IMA with polysomnographic parameters. The pooled diagnostic odds ratio and area under curve were 19.58 and 0.888 (Q* = 0.819), respectively. There was no evidence of publication bias for the association of IMA with OSA.
Conclusion: This meta-analysis suggests that OSA is associated with significantly increased IMA levels which may indicate OS, ischemia and subclinical cardiovascular risk. In the diagnostic test accuracy meta-analysis, IMA showed good accuracy for OSA detection. However, further studies are required to establish its clinical utility.
Keywords: Ischemia-modified albumin; Meta-analysis; Obstructive sleep apnea; Sleep.
Similar articles
-
Impact of continuous positive airway pressure on vascular endothelial growth factor in patients with obstructive sleep apnea: a meta-analysis.Sleep Breath. 2019 Mar;23(1):5-12. doi: 10.1007/s11325-018-1660-4. Epub 2018 Apr 18. Sleep Breath. 2019. PMID: 29671205 Review.
-
The effect of continuous positive airway pressure on circulating malondialdehyde among obstructive sleep apnea patients: a meta-analysis.Sleep Breath. 2020 Dec;24(4):1407-1415. doi: 10.1007/s11325-019-01998-x. Epub 2019 Dec 24. Sleep Breath. 2020. PMID: 31873838
-
Elevated levels of the circulatory ischemia-modified albumin in patients with polycystic ovary syndrome: a meta-analysis.Gynecol Endocrinol. 2018 Oct;34(10):868-874. doi: 10.1080/09513590.2018.1462318. Epub 2018 Apr 14. Gynecol Endocrinol. 2018. PMID: 29656677
-
Effect of continuous positive airway pressure on endothelin-1 in patients with obstructive sleep apnea: a meta-analysis.Eur Arch Otorhinolaryngol. 2019 Mar;276(3):623-630. doi: 10.1007/s00405-018-5225-8. Epub 2018 Dec 3. Eur Arch Otorhinolaryngol. 2019. PMID: 30511103
-
Effects of CPAP therapy on subcutaneous adipose tissue in patients with obstructive sleep apnea: a meta-analysis.Sleep Breath. 2020 Sep;24(3):801-808. doi: 10.1007/s11325-020-02051-y. Epub 2020 Apr 13. Sleep Breath. 2020. PMID: 32285252 Review.
Cited by
-
Analysis of the Ischemia-Modified Albumin as a Potential Biomarker for Cardiovascular Damage in Obstructive Sleep Apnea Patients with Acute Coronary Syndrome.Int J Mol Sci. 2023 May 19;24(10):9019. doi: 10.3390/ijms24109019. Int J Mol Sci. 2023. PMID: 37240363 Free PMC article.
-
NOX4, MDA, IMA and oxidative DNA damage: can these parameters be used to estimate the presence and severity of OSA?Sleep Breath. 2021 Mar;25(1):529-536. doi: 10.1007/s11325-020-02093-2. Epub 2020 May 12. Sleep Breath. 2021. PMID: 32399699
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources