Retentive force variations of stud attachments for implant overdentures
- PMID: 29964247
Retentive force variations of stud attachments for implant overdentures
Abstract
Implant overdentures are considered a standard treatment option by many practitioners, especially for edentulous mandibles. Stud attachments have been used extensively in the construction of these overdentures. In this study, the retentive forces of O-ring/ball and Locator overdenture attachments under various conditions in the mouth were investigated through pull-out tests. In dry testing, the retentive forces of the O-ring/ball attachment started higher than those of the Locator attachment but significantly decreased after 50 insertion-removal cycles (P = 0.014). The Locator attachment had no significant change in its retentive force over time (P = 0.328). In wet testing, a saliva substitute was applied to the stud attachments between cycles. The retentive force of the O-ring/ball attachment increased significantly in wet testing compared to dry testing (P < 0.0001). The retentive force of the Locator system during wet testing did not change significantly from that achieved during dry testing for the first 80 cycles, but then it increased to reach the same levels as the O-ring/ball system at 510 cycles (P < 0.05). Within the limitations of the present study, the results suggest that it is advisable to avoid using O-ring/ball attachments as anchors for implant overdentures in a dry mouth environment. In such cases, Locator attachment or metal-to-metal attachment components would be preferable as implant overdenture anchors. In a saliva-irrigated mouth, there is no significant difference between the retentive properties of the O-ring/ball and Locator attachments over 6-9 months' use.
Keywords: attachments; overdentures; retentive force; xerostomia.
Conflict of interest statement
Disclaimer: The authors report no conflicts of interest pertaining to any of the products or companies discussed in this article.
Similar articles
-
In vitro comparison of the retentive properties of ball and locator attachments for implant overdentures.Int J Oral Maxillofac Implants. 2014 Sep-Oct;29(5):1106-13. doi: 10.11607/jomi.3621. Int J Oral Maxillofac Implants. 2014. PMID: 25216136
-
Effects of in vitro cyclic dislodging on retentive force and removal torque of three overdenture attachment systems.Clin Oral Implants Res. 2014 Apr;25(4):426-34. doi: 10.1111/clr.12156. Epub 2013 Apr 9. Clin Oral Implants Res. 2014. PMID: 23566266
-
Retention and wear behaviors of two implant overdenture stud-type attachments at different implant angulations.J Prosthet Dent. 2017 May;117(5):628-635. doi: 10.1016/j.prosdent.2016.09.027. Epub 2016 Nov 15. J Prosthet Dent. 2017. PMID: 27863857
-
Digital wear analysis and retention of poly-ether-ether-ketone retentive inserts versus conventional nylon inserts in locator retained mandibular overdentures: in-vitro study.Clin Oral Investig. 2024 Aug 6;28(9):468. doi: 10.1007/s00784-024-05831-y. Clin Oral Investig. 2024. PMID: 39105859 Free PMC article. Review.
-
Fabrication of a Mandibular Implant-Supported Overdenture with a New Attachment System: A Review of Current Attachment Systems.Int J Prosthodont. 2017 May/June;30(3):245–247. doi: 10.11607/ijp.5068. Epub 2017 Mar 20. Int J Prosthodont. 2017. PMID: 28319214 Review.
Cited by
-
Retentive force and dislodgment time variations between three implant overdenture stud attachments in an acidic environment: An in-vitro pilot study.Saudi Dent J. 2024 Feb;36(2):368-373. doi: 10.1016/j.sdentj.2023.11.027. Epub 2023 Nov 28. Saudi Dent J. 2024. PMID: 38419987 Free PMC article.
-
The Effect of Number and Distribution of Mini Dental Implants on Overdenture Stability: An In Vitro Study.Materials (Basel). 2022 Apr 20;15(9):2988. doi: 10.3390/ma15092988. Materials (Basel). 2022. PMID: 35591322 Free PMC article.