. 2019 Feb;14(2):409-416.
doi: 10.1007/s11548-018-1816-5. Epub 2018 Jul 2.

Clinical use of an opto-nuclear probe for hybrid sentinel node biopsy guidance: first results

Affiliations

Clinical use of an opto-nuclear probe for hybrid sentinel node biopsy guidance: first results

Sergi Vidal-Sicart et al. Int J Comput Assist Radiol Surg. 2019 Feb.

Abstract

Introduction: Guidelines advocate the use of combined detection techniques to achieve optimal results for sentinel node (SN) biopsy. The fluorescent and radioactive (dual-) tracer ICG-99mTc-nanocolloid has been shown to facilitate SN biopsy in several indications. It was reported that an opto-nuclear probe permitted the detection of near-infrared fluorescence and gamma-rays. The aim of the current study was to evaluate this device in a large patient group and to test it in both open and laparoscopic surgery implications.

Methods: Thirty-three patients scheduled for SN biopsy with the dual-tracer were retrospectively analyzed. Pre-operative lymphoscintigraphy was performed in all patients; in 18 patients (55%), a SPECT/CT scan was also performed. Radioactive and fluorescent signatures in the SNs were assessed in vivo and ex vivo using the opto-nuclear probe.

Results: One or more SNs were identified in all patients (identification rate 100%). Planar lymphoscintigraphic images revealed 95 hot spots that were considered as SNs. This number increased to 103 SNs when SPECT/CT was used. During surgery, 106 SNs were excised. In vivo, the fluorescence mode of the opto-nuclear probe was able to locate 79 SNs (74.5%). When the gamma-ray detection option of the same probe was used, this number increased to 99 SNs (93.3%). Ex vivo analysis revealed fluorescence in 93.3% of the excised nodes and radioactivity in 95.2%.

Conclusions: This study underlines the feasibility of using the dual-tracer/opto-nuclear probe combination for SN resections. The use of the opto-nuclear technology has been extended to laparoscopic surgery. This study also underlines the fluorescence tracing can complement traditional radio-tracing approaches.

Keywords: Bi-modal; Dual-tracer; Fluorescence; Hybrid; Image-guided surgery; SPECT; Sentinel node.

PubMed Disclaimer

References

    1. Gynecol Obstet Fertil. 2016 Apr;44(4):207-10 - PubMed
    1. Eur Urol. 2011 Oct;60(4):826-33 - PubMed
    1. Eur J Nucl Med Mol Imaging. 2013 Dec;40(12):1932-47 - PubMed
    1. Eur Urol. 2014 Mar;65(3):600-9 - PubMed
    1. Int J Gynecol Cancer. 2017 May;27(4):832-837 - PubMed

Substances

LinkOut - more resources