. 2019 Jul;47(8):1984-1993.
doi: 10.1177/0363546518780928. Epub 2018 Jul 5.

Biomechanical Strength of Rotator Cuff Repairs: A Systematic Review and Meta-regression Analysis of Cadaveric Studies

Affiliations

Biomechanical Strength of Rotator Cuff Repairs: A Systematic Review and Meta-regression Analysis of Cadaveric Studies

Brendan Y Shi et al. Am J Sports Med. 2019 Jul.

Abstract

Background: Biomechanical cadaveric studies of rotator cuff repair (RCR) have shown that transosseous equivalent and double-row anchored repairs are stronger than other repair constructs.

Purpose: To identify technical and procedural parameters that most reliably predict biomechanical performance of RCR constructs.

Study design: Systematic review.

Methods: The authors systematically searched the EMBASE and PubMed databases for biomechanical studies that measured RCR performance in cadaveric specimens. The authors performed a meta-regression on the pooled data set with study outcomes (gap formation, failure mode, and ultimate failure load) as dependent variables and procedural parameters (eg, construct type, number of suture limbs) as covariates. Stratification by covariates was performed. An alpha level of .05 was used.

Results: Data from 40 eligible studies were included. Higher number of suture limbs correlated with higher ultimate failure load (β = 38 N per limb; 95% CI, 28 to 49 N) and less gap formation (β = -0.6 mm per limb; 95% CI, -1 to -0.2 mm). Other positive predictors of ultimate failure load were number of sutures, number of mattress stitches, and use of wide suture versus standard suture. When controlling for number of suture limbs, we found no significant differences among single-row anchored, double-row anchored, transosseous equivalent, and transosseous repairs. Higher number of suture limbs and transosseous equivalent repair both increased the probability of catastrophic construct failure.

Conclusion: This study suggests that the number of sutures, suture limbs, and mattress stitches in a RCR construct are stronger predictors of overall strength than is construct type. There is a need to balance increased construct strength with higher risk of type 2 failure.

Keywords: meta-regression; rotator cuff repair; suture; transosseous anchors; transosseous equivalent.

PubMed Disclaimer

Publication types

LinkOut - more resources