. 2018 Jul 1;25(Pt 4):1048-1059.
doi: 10.1107/S1600577518007208. Epub 2018 Jun 17.

More are better, but the details matter: combinations of multiple Fresnel zone plates for improved resolution and efficiency in X-ray microscopy

Affiliations

More are better, but the details matter: combinations of multiple Fresnel zone plates for improved resolution and efficiency in X-ray microscopy

Kenan Li et al. J Synchrotron Radiat. .

Abstract

Fresnel zone plates used for X-ray nanofocusing face high-aspect-ratio nanofabrication challenges in combining narrow transverse features (for high spatial resolution) along with extended optical modulation along the X-ray beam direction (to improve efficiency). The stacking of multiple Fresnel zone plates along the beam direction has already been shown to offer improved characteristics of resolution and efficiency when compared with thin single zone plates. Using multislice wave propagation simulation methods, here a number of new schemes for the stacking of multiple Fresnel zone plates are considered. These include consideration of optimal thickness and spacing in the axial direction, and methods to capture a fraction of the light otherwise diffracted into unwanted orders, and instead bring it into the desired first-order focus. The alignment tolerances for stacking multiple Fresnel zone plates are also considered.

Keywords: Fresnel zone plates; X-ray microscopy; X-ray optics.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Zone plates modulate the phase and magnitude of a transmitted wave so as to direct it to a focus. This can be done in several ways, using magnitude and/or phase modulations on alternating zones of half-wavelength optical path difference to the focus. A simple Fresnel zone plate (a) has an outermost zone width of formula image and a thickness t; it applies a constant magnitude reduction or phase shift across each zone, while a blazed zone plate (b) puts a staircase approximation of a phase ramp across the zone. One can stack several thin Fresnel zone plates (c) to manipulate the wave at several locations leading to the focus, or use thicker zones (d) which are individually tilted to meet the Bragg grating condition or even curved in a volume hologram approach to produce the converging wavefield.
Figure 2
Figure 2
The stacking of multiple thinner zone plates can lead to higher optical performance than can be obtained with a thicker single zone plate. On the left (a) is show the focusing efficiency (in terms of integrated energy fraction as a function of radius from the focal spot center) and, as an inset, the focused intensity profile for the three zone-plate design schemes and parameters outlined in Table 1 ▸. This is for the case of zone plates separated by a very large distance of formula image = 1000 µm relative to the focal length of formula image = 9074 µm for the first, upstream zone plate. The inset shows that the strategy of fixed diameter d gives a higher Rayleigh resolution (smaller radius for the first minimum of the intensity distribution) than the strategies of fixed outermost zone width formula image or fixed zone number N. On the right (b) is shown the integrated energy fraction for a single formula image = 2000 nm-thick zone plate versus four formula image = 500 nm-thick zone plates separated by formula image = 50 µm, and designed according to the fixed diameter d strategy. If multiple thinner zone plates can be aligned with sufficient accuracy, they can offer higher overall focusing efficiency (though in this case the separation between the zone plates is so small that they all have essentially the same numerical aperture, so there is no spatial resolution gain).
Figure 3
Figure 3
Phase profile of the exit wave from (top) a single formula image = 2.0 µm-thick zone plate of gold for 10 keV X-ray focusing, (middle) four 0.5 µm-thick zone plates, and (bottom) ten 0.2 µm-thick zone plates. In each case the phase of the exit wave from the final downstream zone plate is shown. By using multiple thin zone plates, one can better approximate the phase profile of a blazed zone plate (Fig. 1b ▸).
Figure 4
Figure 4
While there might be practical limitations to the number of zone plates formula image that can be stacked together, one can obtain gains in first-order diffraction efficiency formula image that go well beyond the simple thin zone plate expression of equation (1). In (a) we show the efficiency as a function of individual zone plate thickness formula image and cumulative thickness t, where formula image = formula image zone plates are used with with a separation of formula image = 10 µm (for formula image = 45 µm, and formula image = 25 nm for the first zone plate at 10 keV). A single gold zone plate with the optimum thickness formula image = 2.0 µm would give formula image = 32.7%, whereas much higher efficiencies can be obtained by using many more zone plates with slightly higher cumulative thickness. In (b) we show how the stacking of formula image = 8 zone plates, each with a thickness formula image = 0.5 µm, leads to differences in diffraction efficiency as one changes the separation distance formula image between zone plates. Smaller separation distances formula image are preferable but might be impractical, but even with larger separation distances like formula image = 1000 µm one can still obtain an efficiency of formula image = 36% if formula image = 5 zone plates are used. All calculations were for gold zone plates at 10 keV.
Figure 5
Figure 5
Illustration of the Talbot effect. When a periodic diffraction grating is illuminated by a plane wave, the image of the grating is repeated at a Talbot distance of formula image = formula image [equation (10)] where a is the period of the diffraction grating. For a grating period of formula image = 100 nm, and formula image = 0.124 nm (corresponding to 10 keV X-rays), the Talbot distance is formula image = 161 µm. The grating here was assumed to be fully absorptive.
Figure 6
Figure 6
Diffraction efficiency formula image versus separation distance formula image for different thicknesses formula image of individual zone plates, and for two different values of outermost zone width: formula image = 20 nm (a) and formula image = 30 nm (b). For each individual zone thickness formula image and separation distance formula image, the number of stacked zone plates formula image was chosen to give maximum efficiency, as shown in Fig. 4(b) ▸, and the average value of formula image corresponding to a particular value of formula image is indicated. As can be seen, there is a pattern of maxima and minima in the efficiences as a function of separation distance formula image, with the first two maxima denoted by formula image and formula image, and the first two minima denoted by formula image and formula image. These maxima and minima are compared with the Talbot distance [equation (10)] for the outermost zones in Fig. 7 ▸.
Figure 7
Figure 7
Positions of the efficiency maxima formula image and minima formula image shown in Fig. 6 ▸ as a function of varying outermost zone width formula image (a) or diameter d (b). This was done for an individual zone plate thickness of formula image = 0.9 µm. Clearly the separation distances formula image show maxima and minima that scale with outermost zone width formula image rather than diameter d. Also shown on the left is the Talbot distance formula image based on equation (10) for a grating with a period formula image = formula image determined by the outermost zone width. The efficiency maxima and minima scale with formula image, but the ideal separation distance formula image corresponding to formula image is at about one-quarter of the distance formula image.
Figure 8
Figure 8
A normal Fresnel zone plate with 1:1 line:space ratio (a) can be constructed by interlacing two fabrication processes, either on the same side of a thin window (Chao et al., 2005 ▸) (b) or on opposite sides (Mohacsi et al., 2017 ▸) (c). Both of those interlaced processes reduce the limitations produced by the proximity effect in electron beam lithography in the separate fabrication processes. The proximity effect is reduced further if one fabricates zones with a line:space ratio of 1:3 and uses them in the second diffraction order. One can also use complementary zone plates with an opposite pattern of material-filled/open zones. That leads to several options in zone plate stacking: stacking with 1:3 line:space ratio with a regular (d) or complementary (e) second zone plate, or with 1:1 line:space ratio with a regular (f) or complementary second zone plate. These various combinations give different properties for focusing efficiency and focal spot sidelobes, as shown in Fig. 9 ▸.
Figure 9
Figure 9
Stacking of two zone plates with 100 nm outermost zone period, each with formula image = 1 µm thickness, at 10 keV photon energy. Using the four different stacking schemes shown in Fig. 8 ▸, in (a) we show both the radial intensity profile and also the radially integrated energy for formula image = 2 second diffraction order focusing. The 1:3 line:space approach with the second zone plate being a complementary zone plate has a unique property of having very little energy in sidelobes around the central focus spot. In (b) we show the normalized focus intensity for 1:3 line:space stacking with regular and complementary second zone plate as a function of separation distance formula image, demonstrating a crossover between which approach is preferred at half of formula image of equation (13). In (c) we show the focal spot intensity as the line:space ratio is adjusted in both the upstream and (regular) downstream zone plate; the optimum line:space ratio for a variety of separation distances formula image is shown in (d).
Figure 10
Figure 10
Optimum line:space ratio (a) and resulting relative focusing intensity (b) for formula image = 2 second-order focusing as a function of both zone thickness formula image and separation distance formula image. The differences between using a regular or a complementary zone plate for the second optic become larger when thickness formula image approaches 2 µm which corresponds to a π phase shift.
Figure 11
Figure 11
Refocusing zone plates can recapture some of the formula image = −1-order focus light from a conventional zone plate. This is shown schematically in (a), where one can produce a combined optic with a stacked zone plate in the inner diameter and a refocusing zone plate operating in either formula image = 1 or first diffraction order, or formula image = 3 or third diffraction order. The effect on the focus profile and integrated energy as a function of radius is shown in (b), for the cases of a conventional zone plate alone (case C), or with the addition of a refocusing zone plate operating in first diffraction order (case CR1), or with a refocusing zone plate operating in third diffraction order (case CR3). Both refocusing zone plates offer an increase in focal efficiency, with the CR1 case also offering an improvement in spatial resolution. However, in the CR1 case the refocusing zone plate must have finer zone width formula image than the conventional zone plate, and usually the conventional zone plate is fabricated out to the limits of what can be achieved in nanolithography; in the CR3 case, the finest zone width formula image is the same for the conventional (C) and third-order refocusing (R3) zone plates. The parameters for the zone plates used for the calculation of focal intensities (b) are given in Table 2 ▸.
Figure 12
Figure 12
Effect of using both stacked and refocusing zone plates. Four combinations were compared: a conventional zone plate alone (C), or optionally with a stacked zone plate (S), or optionally with a third diffraction order refocusing zone plate (R3). This gives combinations C, CS, CR3 and CSR3 as indicated. On the left (a) is shown the focused intensity profile and radial integral of energy, while on the right (b) is shown the set of axial intensity profiles. Adding a refocusing zone plate provides some increase in focused intensity, but only over a narrow depth of focus range reduced by a factor of formula image due to the presence of the third diffraction order refocusing zone plate (R3). The parameters for the individual zone plates are shown in Table 3 ▸.

Similar articles

Cited by

References

    1. Aristov, V. V., Isoyan, A., Kohn, V., Kuyumchyan, A., Shulakov, E., Snigirev, A. A. & Snigireva, I. (2007). Nucl. Instrum. Methods Phys. Res. A, 575, 238–241.
    1. Attwood, D. & Sakdinawat, A. (2017). X-rays and Extreme Ultraviolet Radiation, 2nd ed. Cambridge University Press.
    1. Chang, C. & Sakdinawat, A. (2014). Nat. Commun. 5, 4243. - PubMed
    1. Chao, W., Harteneck, B. D., Liddle, J. A., Anderson, E. H. & Attwood, D. T. (2005). Nature (London), 435, 1210–1213. - PubMed
    1. Cowley, J. M. & Moodie, A. F. (1957). Acta Cryst. 10, 609–619.