Sequential anastomoses in coronary artery grafting: technical aspects and early and late angiographic results
- PMID: 299802
- DOI: 10.1016/s0003-4975(10)64059-3
Sequential anastomoses in coronary artery grafting: technical aspects and early and late angiographic results
Abstract
The present study concerns itself with the early and late results obtained with aortocoronary vein grafts containing more than 1 coronary anastomosis per graft. The surgical technique is described in detail and some of the hazards are outlined. It is apparent that the use of side-to-side anastomoses (SSAs) leads to a marked increase in blood flow in the proximal portion of the graft (average flow,131 ml/min) and also increases the patency rate of the proximal anastomosis. Thus, 3 of 51 SSAs were obstructed on the early angiogram, and only 1 of the 28 SSAs restudied at one year had become occluded. Although the cumulative--early and late--patency rate (55/66, or 83.3%) of the distal end-to-side anastomoses (ESAs) was not significantly better than that usually seen with conventional vein grafts, it is believed that improvement in the technique and greater awareness of some of its pitfalls will further decrease awareness of some of its pitfalls will further decrease the occlusion rate of distal ESAs. Most occlusions of the ESA appeared related to angulation, which tended to occur in the segment of graft between the proximal and the distal anastomoses. Appropriate modifications in the technique are described that should help to eliminate this difficulty. The use of SSAs allows for grafting of small coronary arteries which, with the conventional single anastomosis technique, are not usually bypassed in view of the high expected failure rate. Thus, of the 9 SSAs performed to 1 mm arteries and studied on two occasions, 8 remained open early after operation and 7 were still patent a year later.
Similar articles
-
Optimal patency rates obtained in coronary artery grafting with circular vein grafts.J Thorac Cardiovasc Surg. 1978 Feb;75(2):161-7. J Thorac Cardiovasc Surg. 1978. PMID: 304942
-
Technique for the coronary snake graft operation.Ann Thorac Surg. 1976 Jul;22(1):58-65. doi: 10.1016/s0003-4975(10)63954-9. Ann Thorac Surg. 1976. PMID: 779687
-
One-year patency control and risk analysis of eSVS®-mesh-supported coronary saphenous vein grafts.J Cardiothorac Surg. 2015 Aug 8;10:108. doi: 10.1186/s13019-015-0293-y. J Cardiothorac Surg. 2015. PMID: 26253565 Free PMC article.
-
Composite arterial grafting.Expert Rev Cardiovasc Ther. 2006 Jul;4(4):523-33. doi: 10.1586/14779072.4.4.523. Expert Rev Cardiovasc Ther. 2006. PMID: 16918271 Review.
-
A novel coronary artery bypass graft design of sequential anastomoses.Ann Biomed Eng. 2010 Oct;38(10):3135-50. doi: 10.1007/s10439-010-0068-5. Epub 2010 May 22. Ann Biomed Eng. 2010. PMID: 20496004 Review.
Cited by
-
Oblique venotomy with parallelogram anastomosis in sequential bypass grafting.Gen Thorac Cardiovasc Surg. 2015 Jul;63(7):422-3. doi: 10.1007/s11748-015-0543-x. Epub 2015 Apr 2. Gen Thorac Cardiovasc Surg. 2015. PMID: 25833180
-
Effect of sequential coronary artery bypass venous grafting on right ventricular functions assessed by tissue Doppler echocardiography.Cardiovasc J Afr. 2012 Mar;23(2):63-6. doi: 10.5830/CVJA-2010-093. Cardiovasc J Afr. 2012. PMID: 22447473 Free PMC article.
-
Sequential femoral-tibial bypass grafting for limb salvage.Ann Surg. 1978 Nov;188(5):685-8. doi: 10.1097/00000658-197811000-00018. Ann Surg. 1978. PMID: 718295 Free PMC article.
-
Patch repair for the seagull deformity of a sequential diamond-shaped coronary anastomosis.JTCVS Tech. 2023 Jan 14;18:63-64. doi: 10.1016/j.xjtc.2023.01.003. eCollection 2023 Apr. JTCVS Tech. 2023. PMID: 37096095 Free PMC article. No abstract available.
-
Influence of graft anastomosis and graft morphology on long-term patency of the saphenous vein after aortocoronary bypass.Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub. 2024 Sep;168(3):223-228. doi: 10.5507/bp.2024.013. Epub 2024 Apr 24. Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub. 2024. PMID: 38666413
MeSH terms
LinkOut - more resources
Full Text Sources