Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2018 Apr 30;10(6):1855.
doi: 10.4022/jafib.1855. eCollection 2018 Apr.

Real-Time Recordings in Cryoballoon Pulmonary Veins Isolation: Comparison Between the 25mm and the 20mm Achieve Catheters

Affiliations

Real-Time Recordings in Cryoballoon Pulmonary Veins Isolation: Comparison Between the 25mm and the 20mm Achieve Catheters

Francesca Salghetti et al. J Atr Fibrillation. .

Abstract

Aims: Real Time Recordings (RTR) of pulmonary vein (PV) activity provide important information in the setting of the 2nd generation Cryoballoon (CB-A), as a funcion of time to isolation. Visualization of RTR with the standard inner lumen mapping catheter (ILMC) 20mm Achieve (AC) is possible in roughly 50% of PVs. A novel 25mm-Achieve Advance (AC-A) has been developed with the aim of increasing the detection of RTR. The purpose of this study is to compare the AC-A with the AC, to feasibility and improvement of RTR.

Methods: We assigned 50 patients with paroxysmal or persistent atrial fibrillation to CB-A PVI, using the AC-A as ILMC. We compared this group with 50 patients, matched for age and left atrial volume, who previously underwent the CB-A PVI using the AC.

Results: RTR were more frequently observed with the AC-A than with the AC (74% vs 49%; p= 0.02). RTR in the left superior PVs was similar in both groups (74% vs 72%, p= 0.8). RTR with the AC-A were equally appreciated in left or right sided, superior or inferior PVs. No significant differences were found in terms of feasibility, procedure fluoroscopy and freezing times, nadir temperatures, and acute PVI.

Conclusions: CB-A PVI with the AC-A is feasible and safe in all PVs. The AC-A has proven significantly superior in visualising RTR if compared to the AC, affording RTR in 74% of PVs.

Keywords: Achieve Advance Catheter; Cryoballoon Pulmonary Vein Isolation; Real Time Recordings; Time To Pulmonary Vein Isolation.

PubMed Disclaimer

Figures

Figure 1A
Figure 1A. Novel 25mm Achieve Advance ILMC
Figure 1B
Figure 1B. Standard 20mm Achieve ILMC
Figure 1C
Figure 1C. Shaft of both ILMC

References

    1. Dorwarth Uwe, Schmidt Martin, Wankerl Michael, Krieg Juergen, Straube Florian, Hoffmann Ellen. Pulmonary vein electrophysiology during cryoballoon ablation as a predictor for procedural success. J Interv Card Electrophysiol. 2011 Dec;32 (3):205–11. - PubMed
    1. Ciconte Giuseppe, Mugnai Giacomo, Sieira Juan, Velagić Vedran, Saitoh Yukio, Irfan Ghazala, Hunuk Burak, Ströker Erwin, Conte Giulio, Di Giovanni Giacomo, Baltogiannis Giannis, Wauters Kristel, Brugada Pedro, de Asmundis Carlo, Chierchia Gian-Battista. On the Quest for the Best Freeze: Predictors of Late Pulmonary Vein Reconnections After Second-Generation Cryoballoon Ablation. Circ Arrhythm Electrophysiol. 2015 Dec;8 (6):1359–65. - PubMed
    1. Chun K R Julian, Stich Marie, Fürnkranz Alexander, Bordignon Stefano, Perrotta Laura, Dugo Daniela, Bologna Fabrizio, Schmidt Boris. Individualized cryoballoon energy pulmonary vein isolation guided by real-time pulmonary vein recordings, the randomized ICE-T trial. Heart Rhythm. 2017 Apr;14 (4):495–500. - PubMed
    1. Chierchia Gian-Battista, de Asmundis Carlo, Namdar Mehdi, Westra Sjoerd, Kuniss Malte, Sarkozy Andrea, Bayrak Fatih, Ricciardi Danilo, Casado-Arroyo Ruben, Rodriguez Manero Moises, Rao Jayakeerthi Y, Smeets Joep, Brugada Pedro. Pulmonary vein isolation during cryoballoon ablation using the novel Achieve inner lumen mapping catheter: a feasibility study. Europace. 2012 Jul;14 (7):962–7. - PubMed
    1. Chierchia Gian-Battista, Namdar Mehdi, Sarkozy Andrea, Sorgente Antonio, de Asmundis Carlo, Casado-Arroyo Rubén, Capulzini Lucio, Bayrak Fatih, Rodriguez-Mañero Moisés, Ricciardi Danilo, Rao Jayakeerthi Y, Overeinder Ingrid, Paparella Gaetano, Brugada Pedro. Verification of pulmonary vein isolation during single transseptal cryoballoon ablation: a comparison between the classical circular mapping catheter and the inner lumen mapping catheter. Europace. 2012 Dec;14 (12):1708–14. - PubMed

LinkOut - more resources