Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2018 Sep;288(3):682-691.
doi: 10.1148/radiol.2018172523. Epub 2018 Jul 10.

Myocardial Delayed Enhancement CT for the Evaluation of Heart Failure: Comparison to MRI

Affiliations
Comparative Study

Myocardial Delayed Enhancement CT for the Evaluation of Heart Failure: Comparison to MRI

Yasutoshi Ohta et al. Radiology. 2018 Sep.

Abstract

Purpose To assess the diagnostic performance of dual-energy CT with myocardial delayed enhancement (MDE) in the detection and classification of myocardial scar in patients with heart failure, with late gadolinium enhancement (LGE) MRI as the standard of reference. Materials and Methods MDE CT and LGE MRI were performed in 44 patients with heart failure (30 men; mean patient age, 66 years ± 14) between 2013 and 2016, and images were retrospectively analyzed. The presence and patterns of MDE on iodine-density and virtual monochromatic (VM) images were assessed by two independent readers. Contrast-to-noise ratio (CNR) and percentage signal intensity increase relative to normal myocardium were measured. Diagnostic performance and area under the receiver operating characteristic curve for MDE CT and kappa values for reader agreement were determined. Results Thirty-five of the 44 patients (80%) demonstrated a focal area of LGE, with a nonischemic pattern in 22 of the 44 patients (50%) and an ischemic pattern in 13 (30%). Iodine-density images demonstrated the highest CNR and percentage signal intensity increase on CT images (P < .05), resulting in the highest diagnostic performance in the detection of any MDE CT abnormality (92% sensitivity [195 of 213 segments] and 98% specificity [481 of 491 segments]). The areas under the receiver operating characteristic curve for iodine-density images and 40-keV VM images in the detection of MDE were 0.97 and 0.95, respectively (P < .001). Kappa values for reader agreement were 0.82 for iodine-density images and 0.72 for 40-keV VM images. Conclusion Myocardial delayed enhancement CT enables accurate detection and localization of scar in patients with heart failure when compared with late gadolinium enhancement MRI, the reference standard.

PubMed Disclaimer

Comment in

Publication types