Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2018 Aug;65(8):1748-1758.
doi: 10.1109/TBME.2017.2764507. Epub 2017 Nov 20.

Evaluation of an Integrated System of Wearable Physiological Sensors for Stress Monitoring in Working Environments by Using Biological Markers

Evaluation of an Integrated System of Wearable Physiological Sensors for Stress Monitoring in Working Environments by Using Biological Markers

Stefano Betti et al. IEEE Trans Biomed Eng. 2018 Aug.

Abstract

Objective: The objectives of this paper are to develop and test the ability of a wearable physiological sensors system, based on ECG, EDA, and EEG, to capture human stress and to assess whether the detected changes in physiological signals correlate with changes in salivary cortisol level, which is a reliable, objective biomarker of stress.

Methods: 15 healthy participants, eight males and seven females, mean age 40.8 ± 9.5 years, wore a set of three commercial sensors to record physiological signals during the Maastricht Acute Stress Test, an experimental protocol known to elicit robust physical and mental stress in humans. Salivary samples were collected throughout the different phases of the test. Statistical analysis was performed using a support vector machine (SVM) classification algorithm. A correlation analysis between extracted physiological features and salivary cortisol levels was also performed.

Results: 15 features extracted from heart rate variability, electrodermal, and electroencephalography signals showed a high degree of significance in disentangling stress from a relaxed state. The classification algorithm, based on significant features, provided satisfactory outcomes with 86% accuracy. Furthermore, correlation analysis showed that the observed changes in physiological features were consistent with the trend of salivary cortisol levels (R2 = 0.714).

Conclusion: The tested set of wearable sensors was able to successfully capture human stress and quantify stress level.

Significance: The results of this pilot study may be useful in designing portable and remote control systems, such as medical devices used to turn on interventions and prevent stress consequences.

PubMed Disclaimer

Publication types