Modeling and Simulation of a Lower Extremity Powered Exoskeleton
- PMID: 30004879
- DOI: 10.1109/TNSRE.2018.2854605
Modeling and Simulation of a Lower Extremity Powered Exoskeleton
Abstract
Lower extremity powered exoskeletons (LEPEs) allow people with spinal cord injury (SCI) to stand and walk. However, the majority of LEPEs walk slowly and users can become fatigued from overuse of forearm crutches, suggesting LEPE design can be enhanced. Virtual prototyping is a cost-effective way of improving design; therefore, this research developed and validated two models that simulate walking with the Bionik Laboratories' ARKE exoskeleton attached to a human musculoskeletal model. The first model was driven by kinematic data from 30 able-bodied participants walking at realistic slow walking speeds (0.2-0.8 m/s) and accurately predicted ground reaction forces (GRF) for all speeds. The second model added upper limb crutches and was driven by 3-D-marker data from five SCI participants walking with ARKE. Vertical GRF had the strongest correlations (>0.90) and root-mean-square error (RMSE) and mediolateral center of pressure trajectory had the weakest (<0.35), for both models. Strong correlations and small RMSE between predicted and measured GRFs support the use of these models for optimizing LEPE joint mechanics and improving LEPE design.
Similar articles
-
Lower limb sagittal kinematic and kinetic modeling of very slow walking for gait trajectory scaling.PLoS One. 2018 Sep 17;13(9):e0203934. doi: 10.1371/journal.pone.0203934. eCollection 2018. PLoS One. 2018. PMID: 30222772 Free PMC article.
-
Estimating upper extremity joint loads of persons with spinal cord injury walking with a lower extremity powered exoskeleton and forearm crutches.J Biomech. 2020 Jun 23;107:109835. doi: 10.1016/j.jbiomech.2020.109835. Epub 2020 May 8. J Biomech. 2020. PMID: 32517865
-
Lower extremity robotic exoskeleton training: Case studies for complete spinal cord injury walking.NeuroRehabilitation. 2017;41(1):97-103. doi: 10.3233/NRE-171461. NeuroRehabilitation. 2017. PMID: 28505991
-
Exoskeletons for Personal Use After Spinal Cord Injury.Arch Phys Med Rehabil. 2021 Feb;102(2):331-337. doi: 10.1016/j.apmr.2019.05.028. Epub 2019 Jun 20. Arch Phys Med Rehabil. 2021. PMID: 31228407 Review.
-
The efficacy of powered orthoses on walking in persons with paraplegia.Prosthet Orthot Int. 2015 Apr;39(2):90-9. doi: 10.1177/0309364613520031. Epub 2014 Feb 18. Prosthet Orthot Int. 2015. PMID: 24549210 Review.
Cited by
-
Integration of Inertial Sensors in a Lower Limb Robotic Exoskeleton.Sensors (Basel). 2022 Jun 16;22(12):4559. doi: 10.3390/s22124559. Sensors (Basel). 2022. PMID: 35746340 Free PMC article.
-
A Human Lower Limb Mechanical Phantom for the Testing of Knee Exoskeletons.IEEE Trans Neural Syst Rehabil Eng. 2023;31:2497-2506. doi: 10.1109/TNSRE.2023.3276424. Epub 2023 Jun 1. IEEE Trans Neural Syst Rehabil Eng. 2023. PMID: 37186529 Free PMC article.
-
Modeling and Simulation of a Human Knee Exoskeleton's Assistive Strategies and Interaction.Front Neurorobot. 2021 Mar 8;15:620928. doi: 10.3389/fnbot.2021.620928. eCollection 2021. Front Neurorobot. 2021. PMID: 33762922 Free PMC article.
-
Wearable Robot Design Optimization Using Closed-Form Human-Robot Dynamic Interaction Model.Sensors (Basel). 2024 Jun 23;24(13):4081. doi: 10.3390/s24134081. Sensors (Basel). 2024. PMID: 39000860 Free PMC article.
-
Modelling the interaction between wearable assistive devices and digital human models-A systematic review.Front Bioeng Biotechnol. 2023 Jan 10;10:1044275. doi: 10.3389/fbioe.2022.1044275. eCollection 2022. Front Bioeng Biotechnol. 2023. PMID: 36704313 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources