The use of O-ring retractors at Caesarean section : A systematic review and meta analysis
- PMID: 30007248
- DOI: 10.1016/j.ejogrb.2018.06.037
The use of O-ring retractors at Caesarean section : A systematic review and meta analysis
Abstract
O-ring retractors (Alexis/Mobius) have been shown to reduce the risk of Surgical site infection (SSI) following general abdominal surgery. The benefit at caesarean section (CS) remains to be established given the relatively high cost.
Objectives: To assess the efficacy of O-ring retractors when used at CS.
Study design: Systematic review and meta-analysis. Electronic databases were searched from inception of each database until January 2018. No language restrictions were applied. All randomised controlled trials (RCTs) which compared the use of an O-ring retractor to routine care at CS were included. Primary outcome was SSI. Secondary outcomes were operating time, estimated blood loss, need for blood transfusion, need to exteriorise the uterus, requirement for additional postoperative analgesia and adequate operative field visualisation. Analysis was performed using Revman 5.3.
Results: 6 RCTs were included in the qualitative synthesis and the meta-analysis. This included 1669 women. The use of O-ring retractors did not reduce the risk of SSI when used at CS RR 0.76 (95% CI 0.34-1.70). Nor did the use of O-ring retractors reduce the operating time, estimated blood loss, the need for blood transfusion or the need for additional postoperative analgesia. The use O-ring retractors did reduce the need for exteriorisation of the uterus RR 0.48 (95% CI 0.33-0.69), and did increase the rate of adequate visualisation of the operative field RR 1.05 (95% CI 1.00-1.10). In a planned subgroup analysis there was a reduction in the rate of SSI with the use of O-ring retractors in women with a BMI < 35 RR 0.34(95% CI 0.12-0.98).
Conclusion: This review has shown that O-ring retractors do not reduce the incidence of the common measurable complications of CS; SSI, blood loss, need for blood transfusion and need for additional postoperative analgesia. There may be a subgroup where these retractors are useful, but present evidence does not justify their routine use at CS.
Keywords: Alexis; Blood loss; CS; Caesarean section; Mobius; O-ring retractors; Operating time; Operative field visualisation; Plastic sheath wound retractor; SSI; Surgical site infection; Uterine exteriorisation; Wound retraction.
Copyright © 2018 Elsevier B.V. All rights reserved.
Similar articles
-
Alexis O-ring wound retractor versus traditional metal retractors for the prevention of postcaesarean surgical site infections.S Afr Fam Pract (2004). 2023 Feb 16;65(1):e1-e6. doi: 10.4102/safp.v65i1.5651. S Afr Fam Pract (2004). 2023. PMID: 36861911 Free PMC article. Clinical Trial.
-
Surgical site infection in cesarean sections with the use of a plastic sheath wound retractor compared to the traditional self-retaining metal retractor.Eur J Obstet Gynecol Reprod Biol. 2016 Aug;203:232-8. doi: 10.1016/j.ejogrb.2016.06.003. Epub 2016 Jun 20. Eur J Obstet Gynecol Reprod Biol. 2016. PMID: 27352285 Clinical Trial.
-
A randomized controlled trial comparing two types of retractors at caesarean delivery.J Obstet Gynaecol. 2017 Nov;37(8):1009-1014. doi: 10.1080/01443615.2017.1316972. Epub 2017 Jun 21. J Obstet Gynaecol. 2017. PMID: 28635352 Clinical Trial.
-
Advanced dressings for the prevention of surgical site infection in women post-caesarean section: A systematic review and meta-analysis.Eur J Obstet Gynecol Reprod Biol. 2021 Dec;267:226-233. doi: 10.1016/j.ejogrb.2021.11.014. Epub 2021 Nov 11. Eur J Obstet Gynecol Reprod Biol. 2021. PMID: 34826671
-
Effect of negative-pressure wound therapy on wound complications in obese women after caesarean birth: a systematic review and meta-analysis.BJOG. 2022 Jan;129(2):196-207. doi: 10.1111/1471-0528.16963. Epub 2021 Nov 8. BJOG. 2022. PMID: 34622545
Cited by
-
Evidence-based surgical procedures to optimize caesarean outcomes: an overview of systematic reviews.EClinicalMedicine. 2024 May 19;72:102632. doi: 10.1016/j.eclinm.2024.102632. eCollection 2024 Jun. EClinicalMedicine. 2024. PMID: 38812964 Free PMC article. Review.
-
Adhesive incisional drapes during cesarean delivery for preventing wound infection: A systematic review and meta-analysis of randomized controlled trials.Eur J Obstet Gynecol Reprod Biol X. 2019 Aug 2;4:100090. doi: 10.1016/j.eurox.2019.100090. eCollection 2019 Oct. Eur J Obstet Gynecol Reprod Biol X. 2019. PMID: 31673692 Free PMC article.
-
Alexis O-ring wound retractor versus traditional metal retractors for the prevention of postcaesarean surgical site infections.S Afr Fam Pract (2004). 2023 Feb 16;65(1):e1-e6. doi: 10.4102/safp.v65i1.5651. S Afr Fam Pract (2004). 2023. PMID: 36861911 Free PMC article. Clinical Trial.
-
Comparison of the Ventral Approach to the Canine Hip Joint Using Gelpi Retractors and an Elastic O-Ring Wound Retractor.Animals (Basel). 2023 Nov 20;13(22):3582. doi: 10.3390/ani13223582. Animals (Basel). 2023. PMID: 38003199 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical