Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2018 Sep;30(9):329-333.
Epub 2018 Jul 15.

Transfemoral Implantation of the Acurate neo for the Treatment of Aortic Regurgitation

Affiliations
  • PMID: 30012890
Free article

Transfemoral Implantation of the Acurate neo for the Treatment of Aortic Regurgitation

Stefan Toggweiler et al. J Invasive Cardiol. 2018 Sep.
Free article

Abstract

Objectives: We report an international experience of transfemoral transcatheter aortic valve replacement (TAVR) using the self-expanding Acurate neo valve (Boston Scientific) in aortic regurgitation.

Methods: This series comprises 20 patients with pure aortic regurgitation undergoing transfemoral TAVR with the Acurate neo prosthesis at nine centers in Europe and Israel.

Results: Mean age was 79 ± 8 years and mean STS score was 8.3 ± 9.3%. Leaflet calcification was none/minimal in 19 patients (95%). Prosthesis size selection was based on perimeter-derived annular diameter, with a tendency to over-size in cases of borderline annuli. One patient required implantation of a second valve. Device success rate was 18/20 (90%). At discharge, aortic regurgitation was none in 14 patients (70%), mild in 5 patients (25%), and moderate in 1 patient (5%). Left ventricular end-diastolic diameter decreased from 58 ± 7 mm at baseline to 53 ± 7 mm before discharge (P<.001). At 30-day follow-up, there was no mortality, no stroke, and 3 patients (15%) had received a permanent pacemaker. New York Heart Association class had improved significantly compared to baseline (85% in class I/II compared to 15% at baseline; P<.001).

Conclusions: In a selected patient population, transfemoral TAVR using the Acurate neo transcatheter heart valve was successful in treating aortic regurgitation, significantly reduced left ventricular dimensions, and improved clinical symptoms.

Keywords: aortic regurgitation; degenerative valve; femoral; transcatheter aortic valve implantation; transcatheter aortic valve replacement.

PubMed Disclaimer

LinkOut - more resources