Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2019 Jan;121(1):69-75.
doi: 10.1016/j.prosdent.2018.04.021. Epub 2018 Jul 14.

Randomized controlled clinical trial of digital and conventional workflows for the fabrication of zirconia-ceramic fixed partial dentures. Part I: Time efficiency of complete-arch digital scans versus conventional impressions

Affiliations
Free article
Randomized Controlled Trial

Randomized controlled clinical trial of digital and conventional workflows for the fabrication of zirconia-ceramic fixed partial dentures. Part I: Time efficiency of complete-arch digital scans versus conventional impressions

Irena Sailer et al. J Prosthet Dent. 2019 Jan.
Free article

Abstract

Statement of problem: Clinical trials are needed to evaluate digital and conventional technologies for providing fixed partial dentures.

Purpose: The purpose of the first part of this clinical study was to test whether complete-arch digital scans were similar to or better than complete-arch conventional impressions regarding time efficiency and participant and clinician perceptions.

Material and methods: Ten participants in need of a posterior tooth-supported 3-unit fixed partial denture were included. Three intraoral digital scanners and subsequent workflows (Lava C.O.S.; 3M [Lava], iTero; Align Technology Inc [iTero], Cerec Bluecam; Dentsply Sirona [Cerec]) were compared with the conventional impression method using polyether (Permadyne; 3M) and the conventional workflow. A computer-generated randomization list was used to determine the sequence of the tested impression procedures for each participant. The time needed for the impression procedures, including the occlusal registration, was assessed. In addition, the participant and clinician perceptions of the comfort and difficulty of the impression were rated by means of visual analog scales. Data were analyzed with the nonparametric paired Wilcoxon test together with an appropriate Bonferroni correction to detect differences among the impression systems (α=.05).

Results: The total time for the complete-arch impressions, including the preparation (powdering) and the occlusal registration, was shorter for the conventional impression than for the digital scans (Lava 1091 ±523 seconds, iTero 1313 ±418 seconds, Cerec 1702 ±558 seconds, conventional 658 ±181 seconds). The difference was statistically significant for 2 of the 3 digital scanners (iTero P=.001, Cerec P<.001). The clinicians preferred the conventional impression to the digital scans. Of the scanning systems, the system without the need for powdering was preferred to the systems with powdering. No impression method was clearly preferred over others by the participants.

Conclusions: For complete-arch impressions, the conventional impression procedures were objectively less time consuming and subjectively preferred by both clinicians and participants over digital scan procedures.

PubMed Disclaimer

Comment in

Publication types

LinkOut - more resources