Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2018 Sep;160(9):1681-1689.
doi: 10.1007/s00701-018-3641-6. Epub 2018 Jul 26.

Intraoperative computed tomography as reliable navigation registration device in 200 cranial procedures

Affiliations

Intraoperative computed tomography as reliable navigation registration device in 200 cranial procedures

Barbara Carl et al. Acta Neurochir (Wien). 2018 Sep.

Abstract

Background: Registration accuracy is a main factor influencing overall navigation accuracy. Standard fiducial- or landmark-based patient registration is user dependent and error-prone. Intraoperative imaging offers the possibility for user-independent patient registration. The aim of this paper is to evaluate our initial experience applying intraoperative computed tomography (CT) for navigation registration in cranial neurosurgery, with a special focus on registration accuracy and effective radiation dose.

Methods: A total of 200 patients (141 craniotomy, 19 transsphenoidal, and 40 stereotactic burr hole procedures) were investigated by intraoperative CT applying a 32-slice movable CT scanner, which was used for automatic navigation registration. Registration accuracy was measured by at least three skin fiducials that were not part of the registration process.

Results: Automatic registration resulted in high registration accuracy (mean registration error: 0.93 ± 0.41 mm). Implementation of low-dose scanning protocols did not impede registration accuracy (registration error applying the full dose head protocol: 0.87 ± 0.36 mm vs. the low dose sinus protocol 0.72 ± 0.43 mm) while a reduction of the effective radiation dose by a factor of 8 could be achieved (mean effective radiation dose head protocol: 2.73 mSv vs. sinus protocol: 0.34 mSv).

Conclusion: Intraoperative CT allows highly reliable navigation registration with low radiation exposure.

Keywords: Effective radiation dose; Intraoperative computed tomography; Intraoperative imaging; Navigation accuracy; Navigation registration.