Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Case Reports
. 2019 Apr 1;16(4):451-454.
doi: 10.1093/ons/opy170.

A Novel Technique for Prevention of Subarachnoid-Pleural Fistula After Incidental Durotomy During Transthoracic Spinal Surgery

Affiliations
Case Reports

A Novel Technique for Prevention of Subarachnoid-Pleural Fistula After Incidental Durotomy During Transthoracic Spinal Surgery

Kevin D He et al. Oper Neurosurg. .

Abstract

Background: Subarachnoid-pleural fistulas (SPFs) are rare but significant complications of transthoracic spinal surgery. Whether noted intraoperatively or in the postoperative period, SPF requires implementation of aggressive management, with consideration given to direct surgical repair. Additionally, the physical constraints of the thoracic cavity often hinder direct SPF repair.

Objective: To present a novel operative technique that can be used to easily and quickly address incidental durotomy incurred during transthoracic spinal surgery while working within the confines of the thorax.

Methods: Surgical hemostatic clips were used to affix a patch-graft of dural substitute to the parietal pleura surrounding the site of a transthoracic spinal decompression in which an incidental durotomy was incurred. The patch-graft was augmented with the application of biological glue and was successful in preventing symptomatic SPF.

Results: The use of surgical clips to affix a patch graft is a quick, easy, and effective means of addressing an incidental durotomy during thoracotomy and preventing SPF. The clip applier is significantly easier to maneuver within the narrow working channel of the thorax than are instruments used during direct repair.

Conclusion: Preventing SPF can be challenging. The physical constraints of the thoracic cavity make water-tight repair difficult and time-consuming, particularly when the morphology of the dural tear prevents primary apposition of the defect. The authors present a novel technique of preventing development of SPF using hemostatic clips to simply and quickly affix suturable dural substitute to the parietal pleura overlying the site of an incidental durotomy.

Keywords: CSF-pleural fistula; Durotomy repair; Subarachnoid-pleural fistula; Thoracic spinal surgery; Thoracotomy.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources