Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Jan;33(1):94-103.
doi: 10.1177/0269215518791000. Epub 2018 Aug 7.

Validity and reproducibility of the Functional Gait Assessment in persons after stroke

Affiliations

Validity and reproducibility of the Functional Gait Assessment in persons after stroke

Maijke Van Bloemendaal et al. Clin Rehabil. 2019 Jan.

Abstract

Objective:: To evaluate construct validity and reproducibility of the Functional Gait Assessment (FGA) for measuring walking balance capacity in persons after stroke.

Design:: Cross-sectional study.

Setting:: Inpatient and outpatient rehabilitation center.

Subjects:: Fifty-two persons post-stroke (median (25% and 75% percentiles)) time post-stroke 6 (5-10) weeks) with independent walking ability (mean gait speed 1.1 ± .4 m/s).

Methods:: Subjects completed a standardized FGA twice within one to eight days by the same investigator. Validity was evaluated by testing hypotheses on the association with two timed walking tests, Berg Balance Scale, and the mobility domain of the Stroke Impact Scale using correlation coefficients ( r), and with Functional Ambulation Categories using the Kruskal-Wallis test. Reproducibility of FGA scores was assessed with intraclass correlation coefficient and standard error of measurement.

Results:: Subjects scored a median of 22 out of 30 points at the first FGA. Moderate to high significant correlations ( r .61-.83) and significant differences in FGA median scores between the Functional Ambulation Categories were found. Eight hypotheses (80%) could be confirmed. Inter-rater, intra-rater, and test-retest reliability of the total scores were excellent. The standard error of measurement and minimal detectable change were 2 and 6 points, respectively. No relevant ceiling effect was observed.

Conclusion:: The FGA demonstrated good measurement properties in persons after stroke and yielded no ceiling effect in contrast to other capacity measures. In clinical practice, a measurement error of 6 points should be taken into account in interpreting changes in walking balance.

Keywords: Functional Gait Assessment; balance; reproducibility; stroke; walking.

PubMed Disclaimer

LinkOut - more resources