A novel chemical sensor with multiple all-solid-state electrodes and its application in freshwater environmental monitoring
- PMID: 30101778
- DOI: 10.2166/wst.2018.310
A novel chemical sensor with multiple all-solid-state electrodes and its application in freshwater environmental monitoring
Abstract
Freshwater quality detection is important for pollution control. Three important components of water quality are pH, ammonia and dissolved H2S and there is an urgent need for a high-precision sensor for simultaneous and continuous measurement. In this study, all-solid-state electrodes of Eh, pH, NH4 + and S2- were manufactured and mounted to a wireless chemical sensor with multiple parameters. Calibration indicated that the pH electrode had a Nernst response with slope of 53.174 mV; the NH4 + electrode had a detection limit of 10-5 mol/L (Nernst response slope of 53.56 mV between 10-1 to 10-4 mol/L). Ag/Ag2S has a detection limit of 10-7 mol/L (Nernst response slope of 28.439 mV). The sensor was cylindrical and small with low power consumption and low storage demand to achieve continuous in-situ monitoring for long periods. The sensor was tested for 10 days in streams at Trawsgoed Dairy farm in Aberystwyth, UK. At the intensively farmed Trawsgoed, the concentration of NH4 + in the stream rose sharply after the application of slurry to adjacent fields. Further, the stream was overhung with extensive vegetation and exhibited changes in pH, which correlated with photosynthetic activity. Measurements of S2- were stable throughout the week. Our data demonstrate the applicability of our multiple electrode sensor.
Similar articles
-
Construction of Nitrate-selective Electrodes and Monitoring of Nitrates in Hydroponic Solutions.Anal Sci. 2018 Dec 10;34(12):1373-1377. doi: 10.2116/analsci.18P333. Epub 2018 Aug 24. Anal Sci. 2018. PMID: 30146544
-
Fabrication of new solid state phosphate selective electrodes for environmental monitoring.Talanta. 2011 Feb 15;83(5):1491-5. doi: 10.1016/j.talanta.2010.11.045. Epub 2010 Nov 26. Talanta. 2011. PMID: 21238742
-
Platinum electrode coated with a bentonite-carbon composite as an environmental sensor for detection of lead.Anal Bioanal Chem. 2006 Nov;386(5):1559-65. doi: 10.1007/s00216-006-0727-4. Epub 2006 Sep 16. Anal Bioanal Chem. 2006. PMID: 16983532
-
Determination of subnanomolar concentrations of cobalt by adsorptive stripping voltammetry at a bismuth film electrode.Anal Bioanal Chem. 2005 Aug;382(7):1678-82. doi: 10.1007/s00216-005-3358-2. Epub 2005 Jul 14. Anal Bioanal Chem. 2005. PMID: 16021422
-
Review of the occurrence, treatment technologies, and detection methods for saxitoxins in freshwaters.J Water Health. 2024 Aug;22(8):1472-1490. doi: 10.2166/wh.2024.106. Epub 2024 Jul 22. J Water Health. 2024. PMID: 39212282 Review.
Cited by
-
Dual fluorescent hollow silica nanofibers for in situ pH monitoring using an optical fiber.Nanoscale Adv. 2023 Feb 6;5(8):2180-2189. doi: 10.1039/d2na00943a. eCollection 2023 Apr 11. Nanoscale Adv. 2023. PMID: 37056611 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources