Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2018 Dec 1:272:179-184.
doi: 10.1016/j.ijcard.2018.08.017. Epub 2018 Aug 10.

Long-term use of the wearable cardioverter defibrillator in patients with explanted ICD

Affiliations

Long-term use of the wearable cardioverter defibrillator in patients with explanted ICD

Georgy Kaspar et al. Int J Cardiol. .

Abstract

Objectives: To evaluate the effectiveness of wearable cardioverter defibrillator (WCD) use in protecting patients from sudden cardiac arrest (SCA) while they were treated in nonhospital settings until re-implantation of an Implantable cardioverter-defibrillator (ICD) was feasible. We sought to determine whether the WCD could be successfully utilized long term (≥1 year) after ICD extraction in patients at continued risk of SCD in which ICD re-implantation was not practical.

Background: ICDs have proven to improve mortality in patients for both secondary and primary prevention of SCA. Increased ICD implantation in older patients with comorbid conditions has resulted in higher rates of cardiac device infections. Currently, a wearable cardioverter defibrillator (WCD) is an alternative management for SCA prevention in specific cases.

Methods: This a retrospective analysis based on consecutive WCD patients who underwent ICD explant due to device-related infections or mechanical reasons between April 2007 and July 2014. A total of 102 patients were identified from the national database maintained by ZOLL (Pittsburgh, PA, USA). We analyzed the reason for WCD use, demographic information, device data, compliance and duration of WCD use, detected arrhythmias and therapies, and reason for discontinuing WCD use.

Results: In these long term WCD users, average length of WCD use was 638 ± 361 days. Nine patients (8.8%) had a sustained ventricular arrhythmia that was successfully resuscitated by the WCD. Six patients (5.8%) experienced inappropriate shocks. Two patients (1.9%) died of asystole events while wearing the WCD and an additional 10 patients died while not monitored by the WCD. Thirty-nine patients (38.2%) ended WCD use when a new ICD was implanted and 15 patients (14.7%) were still wearing the WCD at the time of analysis.

Conclusions: We found that extending use of the WCD to ≥1 year is a safe and effective alternative treatment for patients with explanted ICDs who are not pacemaker dependent.

Keywords: Cardiac device infections (CDI); Implantable cardioverter-defibrillator (ICD); Sudden cardiac arrest (SCA); Wearable cardioverter defibrillator (WCD).

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources