Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2018 Sep;232(9):949-961.
doi: 10.1177/0954411918794718. Epub 2018 Aug 18.

Additively manufactured versus conventionally pressed cranioplasty implants: An accuracy comparison

Affiliations
Free article
Comparative Study

Additively manufactured versus conventionally pressed cranioplasty implants: An accuracy comparison

Sean Peel et al. Proc Inst Mech Eng H. 2018 Sep.
Free article

Abstract

This article compared the accuracy of producing patient-specific cranioplasty implants using four different approaches. Benchmark geometry was designed to represent a cranium and a defect added simulating a craniectomy. An 'ideal' contour reconstruction was calculated and compared against reconstructions resulting from the four approaches -'conventional', 'semi-digital', 'digital - non-automated' and 'digital - semi-automated'. The 'conventional' approach relied on hand carving a reconstruction, turning this into a press tool, and pressing titanium sheet. This approach is common in the UK National Health Service. The 'semi-digital' approach removed the hand-carving element. Both of the 'digital' approaches utilised additive manufacturing to produce the end-use implant. The geometries were designed using a non-specialised computer-aided design software and a semi-automated cranioplasty implant-specific computer-aided design software. It was found that all plates were clinically acceptable and that the digitally designed and additive manufacturing plates were as accurate as the conventional implants. There were no significant differences between the additive manufacturing plates designed using non-specialised computer-aided design software and those designed using the semi-automated tool. The semi-automated software and additive manufacturing production process were capable of producing cranioplasty implants of similar accuracy to multi-purpose software and additive manufacturing, and both were more accurate than handmade implants. The difference was not of clinical significance, demonstrating that the accuracy of additive manufacturing cranioplasty implants meets current best practice.

Keywords: Additive manufacturing; accuracy; co-ordinate measurement; computer-aided design; cranioplasty; implant; rapid prototyping; surgery.

PubMed Disclaimer

Publication types

LinkOut - more resources