Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2018 Dec;17(6):553-558.
doi: 10.1016/j.hbpd.2018.08.002. Epub 2018 Aug 7.

It is necessary to exam bottom and top slide smears of EUS-FNA for pancreatic cancer

Affiliations

It is necessary to exam bottom and top slide smears of EUS-FNA for pancreatic cancer

Jong-Chan Lee et al. Hepatobiliary Pancreat Dis Int. 2018 Dec.

Abstract

Background: Despite many reports on the diagnostic yield of cytology from endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA), inter-slide differences are unknown. This prospective study aimed to compare diagnostic yield and cellular characteristics of bottom slides (BS) and top slides (TS) from EUS-FNA cytology performed without an on-site cytopathologist.

Methods: In patients with suspected pancreatic cancer on previous imaging explorations, a single endoscopist performed EUS-FNA and obtained 2 sets of cytology slide (8 BS and 8 TS), 1 cellblock slide, and 1 biopsy slide. Both slide sets were randomly assigned. A cytopathologist with more than 10 years of expertise in pancreatic cytopathology blindly inspected and compared two slide sets.

Results: In total, 73 specimens [42 head (57.5%), 16 body (21.9%), and 15 tail (20.5%)] were acquired for final analysis. Seventy-one cases were finally diagnosed with pancreatic cancer. The sensitivity and specificity of BS were 80.3% and 100.0%; and of TS 78.9% and 100.0%, respectively. In analyzing inter-slide difference, 66 cases (90.4%) showed consistent results between BS and TS. However, seven (9.6%) were positive only in one slide sets (4 BS and 3 TS). The proportions of specimens more than moderate and high cellularity were 75.3% and 60.3% in both slide sets (P> 0.99), and the proportion of artifact-free sets were 50.7%, and 52.1% for the BS and TS, respectively (P= 0.869).

Conclusions: Although BS and TS exhibited highly consistent diagnostic yields in cytologic smears from EUS-FNA, the proportion of inter-slide discordance is clinically considerable. Both slide sets need to be examined if there is no on-site cytopathologist.

Keywords: Cytology; Endoscopic ultrasound-guided fine-needle aspiration; Pancreatic neoplasm.

PubMed Disclaimer

LinkOut - more resources