Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2018 Aug:52:56-64.
doi: 10.1016/j.ejmp.2018.06.634. Epub 2018 Jun 21.

The International Atomic Energy Agency action plan on radiation protection of patients and staff in interventional procedures: Achieving change in practice

Affiliations
Review

The International Atomic Energy Agency action plan on radiation protection of patients and staff in interventional procedures: Achieving change in practice

V Tsapaki et al. Phys Med. 2018 Aug.

Abstract

Introduction: The International Atomic Energy Agency (IAEA) organized the 3rd international conference on radiation protection (RP) of patients in December 2017. This paper presents the conclusions on the interventional procedures (IP) session.

Material and methods: The IAEA conference was conducted as a series of plenary sessions followed by various thematic sessions. "Radiation protection of patients and staff in interventional procedures" session keynote speakers presented information on: 1) Risk management of skin injuries, 2) Occupational radiation risks and 3) RP for paediatric patients. Then, a summary of the session-related papers was presented by a rapporteur, followed by an open question-and-answer discussion.

Results: Sixty-seven percent (67%) of papers came from Europe. Forty-four percent (44%) were patient studies, 44% were occupational and 12% were combined studies. Occupational studies were mostly on eye lens dosimetry. The rest were on scattered radiation measurements and dose tracking. The majority of patient studies related to patient exposure with only one study on paediatric patients. Automatic patient dose reporting is considered as a first step for dose optimization. Despite efforts, paediatric IP radiation dose data are still scarce. The keynote speakers outlined recent achievements but also challenges in the field. Forecasting technology, task-specific targeted education from educators familiar with the clinical situation, more accurate estimation of lens doses and improved identification of high-risk professional groups are some of the areas they focused on.

Conclusions: Manufacturers play an important role in making patients safer. Low dose technologies are still expensive and manufacturers should make these affordable in less resourced countries. Automatic patient dose reporting and real-time skin dose map are important for dose optimization. Clinical audit and better QA processes together with more studies on the impact of lens opacities in clinical practice and on paediatric patients are needed.

Keywords: Occupational dose; Paediatric dose; Radiation protection; Risk management of patients.