[Radiation reduction in interventional electrophysiology : Results from operators with different levels of experience]
- PMID: 30155562
- DOI: 10.1007/s00399-018-0589-4
[Radiation reduction in interventional electrophysiology : Results from operators with different levels of experience]
Abstract
Background: Radiation exposure in the catherization laboratory is associated with significant health risks. It is unclear whether a reduction of radiation exposure with the use of "near-zero fluoroscopy" protocols is possible when applied by less experienced operators.
Methods: Consecutive ablation procedures with the use of a 3D mapping system were analyzed. Three time periods were analyzed. During the first period (standard), no specific radiation-reduction protocol was used. During the second period (initial phase of radiation reduction) a near "near-zero fluoroscopy" protocol was implemented; however, the majority of procedures were performed by an expert. During the third period (routine use of radiation reduction), less experienced operators (fellow and beginner) performed a growing number of procedures with the "near-zero fluoroscopy" protocol.
Results: In all, 290 procedures were analyzed. After implementation of a radiation-reduced protocol, a significant reduction of radiation exposure was observed (standard 850 ± 831.7 vs. initial phase 197.2 ± 481.8 μGy/m2, p < 0.001, and vs. routine use 283 ± 493.8 μGy/m2, p < 0.001). No significant difference was observed between the initial phase and routine phase (p = 1). Over the three periods, the proportion of procedures performed by less experienced operators grew significantly for complex (fellow: 0% vs. 10% vs. 30%; p < 0.001) and noncomplex procedures (fellow: 30% vs. 39% vs. 49%; beginner: 15% vs. 38% vs. 34%; p = 0.002). Complication rates were not significantly different.
Conclusions: Implementation of a radiation-reduced protocol leads to a significant reduction of radiation exposure even in less experienced operators during training.
Keywords: Fluoroscopy reduction; Interventional electrophysiology; Operator experience; Radiation exposure; Training.
Similar articles
-
Implementation of a near-zero fluoroscopy approach in interventional electrophysiology: impact of operator experience.J Interv Card Electrophysiol. 2018 Apr;51(3):215-220. doi: 10.1007/s10840-018-0333-3. Epub 2018 Feb 19. J Interv Card Electrophysiol. 2018. PMID: 29460234
-
Effectiveness of the implementation of a simple radiation reduction protocol in the catheterization laboratory.Cardiovasc Revasc Med. 2016 Jul-Aug;17(5):328-32. doi: 10.1016/j.carrev.2016.03.012. Epub 2016 Mar 30. Cardiovasc Revasc Med. 2016. PMID: 27085219
-
Pushing the limits: establishing an ultra-low framerate and antiscatter grid-less radiation protocol for left atrial ablations.Europace. 2018 Apr 1;20(4):604-607. doi: 10.1093/europace/eux010. Europace. 2018. PMID: 28339980
-
Occupational radiation doses to operators performing cardiac catheterization procedures.Health Phys. 2008 Mar;94(3):211-27. doi: 10.1097/01.HP.0000290614.76386.35. Health Phys. 2008. PMID: 18301095 Review.
-
Practical guidance to reduce radiation exposure in electrophysiology applying ultra low-dose protocols: a European Heart Rhythm Association review.Europace. 2023 Jul 4;25(7):euad191. doi: 10.1093/europace/euad191. Europace. 2023. PMID: 37410906 Free PMC article. Review.
References
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources