Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Aug;39(8):1837-1844.
doi: 10.1007/s10792-018-1012-1. Epub 2018 Sep 4.

Observation of anterior chamber volume after cataract surgery with swept-source optical coherence tomography

Affiliations

Observation of anterior chamber volume after cataract surgery with swept-source optical coherence tomography

Minjie Chen et al. Int Ophthalmol. 2019 Aug.

Abstract

Purpose: To investigate the changes in the anterior chamber volume (ACV) with swept-source optical coherence tomography (SS-OCT) after cataract surgery and the factors that influence these ACV changes.

Methods: This was a prospective cohort study. Fifty-one patients who underwent cataract surgery were enrolled. Their ACV, anterior chamber depth, and angle widths were measured with SS-OCT before and 1 day, 1 week, and 1 month after surgery. The associations between the changes in ACV and posterior vitreous detachment (PVD) and axial length (AXL) were determined.

Results: Compared with the preoperative volume, ACV increased significantly at all three time points after surgery (all p < 0.001). ACV was greater at 1 week after surgery than at 1 day after surgery (p < 0.001). Both AXL and the presence of PVD were significantly associated with the change in ACV at 1 day after surgery (p = 0.005). However, neither PVD nor AXL affected the change in ACV between 1 day and 1 week after surgery.

Conclusions: ACV stabilized in the first week after cataract surgery. The absorption of irrigation fluid and balanced salt solution in the vitreous cavity contributed to the change in ACV 1 week after surgery. Eyes with longer AXL and PVD tended to show less change in ACV at 1 day after surgery.

Keywords: Anterior chamber volume; Axial length; Cataract surgery; Optical coherence tomography; Phacoemulsification; Posterior vitreous detachment.

PubMed Disclaimer

References

    1. J Cataract Refract Surg. 2008 Aug;34(8):1400-2 - PubMed
    1. Invest Ophthalmol Vis Sci. 2009 Jun;50(6):2927-31 - PubMed
    1. J Cataract Refract Surg. 2010 Jan;36(1):53-7 - PubMed
    1. J Cataract Refract Surg. 2010 Jan;36(1):161-3 - PubMed
    1. Graefes Arch Clin Exp Ophthalmol. 2012 Dec;250(12):1827-34 - PubMed

LinkOut - more resources