Evaluation of three commercial screening tests for AIDS virus antibodies
- PMID: 3019124
- DOI: 10.1093/ajcp/86.3.357
Evaluation of three commercial screening tests for AIDS virus antibodies
Abstract
Three commercial enzyme-linked immunosorbent assays (ELISA) for acquired immune deficiency syndrome (AIDS) virus antibodies were evaluated using serum that had been characterized by an ELISA and western blot procedure developed at the University of California at Davis (UCD). Each of the commercial tests was more specific than the UCD ELISA, but the UCD ELISA was more sensitive in the detection of sera that lacked reactivity by western blot to the envelope glycoprotein (gp-41). The HTLV-III Bio-EnzaBead (Litton Bionetics, Charleston, SC) was less sensitive and specific than the Abbott HTLV-III EIA (Abbott Laboratories, North Chicago, IL) or the Virgo HTLV-III ELISA (Electro-Nucleonics Inc., Columbia, MD). Overall, 22.9% (57 of 250) and 51.0% of sera that were repeatedly (X2) positive by commercial screening kits tested at blood donor centers and clinical laboratories, respectively, were confirmed by western blot. These results indicate that the screening assays for AIDS virus antibodies are not equal in performance and that positive screening test results must be confirmed by a more specific test like western blot before results are released.
Similar articles
-
Determination of antibodies against LAV/HTLV III: comparative evaluation of four different commercial test kits.AIDS Res. 1986 Spring;2(2):93-7. doi: 10.1089/aid.1.1986.2.93. AIDS Res. 1986. PMID: 3013224
-
[Detection of HTLV-III antibodies using ELISA and the western blot].Wien Klin Wochenschr. 1985 Nov 22;97(22):829-32. Wien Klin Wochenschr. 1985. PMID: 3002046 German.
-
Variations in Western blot banding patterns of human T-cell lymphotropic virus type III/lymphadenopathy-associated virus.J Clin Microbiol. 1987 Jan;25(1):81-4. doi: 10.1128/jcm.25.1.81-84.1987. J Clin Microbiol. 1987. PMID: 3540002 Free PMC article.
-
Performance evaluation of the Abbott HTLV III EIA, a test for antibody to HTLV III in donor blood.Am J Clin Pathol. 1986 Aug;86(2):180-5. doi: 10.1093/ajcp/86.2.180. Am J Clin Pathol. 1986. PMID: 3017089
-
Anti-HTLV-III testing of blood donors: reproducibility and confirmability of commercial test kits.Transfusion. 1985 Jul-Aug;25(4):395-7. doi: 10.1046/j.1537-2995.1985.25485273826.x. Transfusion. 1985. PMID: 2992129
Cited by
-
Antigen detection for human immunodeficiency virus.Clin Microbiol Rev. 1989 Jul;2(3):241-9. doi: 10.1128/CMR.2.3.241. Clin Microbiol Rev. 1989. PMID: 2670189 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical