Higher Critical Shoulder Angle and Acromion Index Are Associated With Increased Retear Risk After Isolated Supraspinatus Tendon Repair at Short-Term Follow Up
- PMID: 30195956
- DOI: 10.1016/j.arthro.2018.05.029
Higher Critical Shoulder Angle and Acromion Index Are Associated With Increased Retear Risk After Isolated Supraspinatus Tendon Repair at Short-Term Follow Up
Abstract
Purpose: To evaluate the effect of critical shoulder angle (CSA), acromion index (AI), and glenoid inclination (GI) on the postoperative healing rate after arthroscopic supraspinatus tendon repair.
Methods: Patients after arthroscopic repair of a symptomatic, unilateral, single-tendon, full-thickness supraspinatus tear in whom nonoperative management had failed were retrospectively reviewed. Magnetic resonance imaging (MRI) studies were obtained 6 months postoperatively and were evaluated by 2 independent observers. Repair integrity was classified as either intact or torn. Preoperative true anteroposterior radiographs were used to measure CSA, AI, and GI.
Results: Fifty-seven patients were evaluated 6 months postoperatively. The mean patient age at surgery was 54.7 ± 7.7 years. On MRI studies, 41 patients (71.9%) had an intact repair and 16 patients (28.1%) had a full-thickness retear. There were no significant differences between the intact and retear group in regard to patient age (P = .648), initial tear size (P = .205), or fatty degeneration (P = .508). The mean CSA for the retear group (37° ± 4°) was significantly higher than that in the intact group (35° ± 3°; P = .014). If the CSA was >38°, the odds ratio of having a retear was 3.78 (95% confidence interval 1.05 to 13.58; P = .042). Average AI for the retear group (0.73 ± 0.09) was significantly higher than that in the intact group (0.69 ± 0.06; P = .049). The mean GI was 17° ± 6° for the intact group and 16° ± 6° for the retear group (P = .739).
Conclusions: At short-term follow-up, higher CSA and AI significantly increased the retear risk after arthroscopic supraspinatus tendon repair. CSA >38° increased the retear risk almost 4-fold. Overall GI was elevated but did not correlate with failure rate.
Level of evidence: III, case control study.
Copyright © 2018 Arthroscopy Association of North America. All rights reserved.
Comment in
-
Editorial Commentary: Critical Shoulder Angle: Perhaps Not So "Critical" for Clinical Outcomes Following Rotator Cuff Repair.Arthroscopy. 2018 Oct;34(10):2755-2756. doi: 10.1016/j.arthro.2018.06.020. Arthroscopy. 2018. PMID: 30286875
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials